SpringWell SMARTFLUSH SF103B Fitting Instructions Download Page 1

Technical Support

If you have any further technical queries, please contact technical support on 01924-420029.

PLEASE DO NOT RETURN ANY ITEM WITHOUT AUTHORISATION
PLEASE LEAVE THESE INSTRUCTIONS WITH CUSTOMER

-------------------------------------------------------------------------------------------------------------------------------------

Guarantee

This product is guaranteed from date of purchase to be free from manufacturing defects for a period of 1 
year (Extended warranty available) with the following conditions :
1) The product has been properly installed as per instructions.
2) Damage due to water ingress to controller, debris from water supply, vandalism or misuse are not 
included. Statutory rights are not affected.
Service  : Woodroyd Electronic Services Ltd, 52 Ashbourne Drive, Cleckheaton BD19 2HZ
_______________________________________________________________________________

Environmental information

This product may contain susbstances that can be hazardous to the environment if not disposed of 
properly. Electrical and electronic equipment should not be dumped with general household waste but 
must be separately collected for proper treatment and recovery. The crossed-out bin symbol is a 
reminder of the need to dispose of the product properly at end of life; in this way you will assist in the 
recovery, recycling and re-use of many of the materials in this product and help to reduce the amount of 
electrical and electronic waste ending up in landfill and to improve quality of life by preventing the release 
of potentially hazardous substances into the environment. Please contact us for information on disposal 
arrangements. Where possible please recycle your packaging.

Producer registration number WEE/DB0002ZR

_________________________________________________________________________________

Carefully designed and distributed by:
SPRINGWELL MICROELECTRONICS LTD, 197 Raikes Lane, Birstall, Batley, West Yorkshire WF17 9QF
The manufacturer reserves the right due to continuous development to change specifications without notice

Tel: 01924 420029    Fax: 0870 7062353 e-mail: 

[email protected]

www.springwellmicro.co.uk

Producer registration number WEE/DB0002ZR

sf2insv2.6.odt

SMARTFLUSH SF103B FITTING INSTRUCTIONS

Smartflush ensures good hygiene while minimising water usage in Gents' urinals.
Pack contains: sensing/control unit with battery; valve, assembled cable; clips, screws, wallplugs.

How Smartflush works

Smartflush stands by until movement is detected, then waits before filling and flushing the cistern

Installation

1)

 Fit back box

 of control unit on the wall or ceiling where it can be seen.

2) Turn off water supply. Fully open (or remove) any existing trickle cock. Ensure that there is an 
isolating valve in the feed to the new valve (to comply with water byelaws). Flush pipe of any debris. 
Cut out 30mm of pipe feeding cistern and 

fit valve

.

NB! It is very important to fit valve the right way round, the Asco valve is marked 'IN' for inlet.  
3) 

Fit cable

 and gland to box. (If too short, replace with longer 1mm

cable, 

polarity important

).

4) 

Set internal switches

 1 and 2 which adjust the cycle time, i.e. the time from detection to end of 

flush. (see diagram above) and ensure switch 3 is on.

Switch settings

1 Off & 2 off = 20 minute cycle
1 On & 2 off = 30 minute cycle
1 Off & 2 on = 40 minute cycle
1 On & 2 on = 60 minute cycle

The cycle time should be set taking into account 
customer requirements and water byelaws on the 
amount of water used. A 30 minute cycle caters for 
most users.

3 Off

= disable manual flush button

3 On

= enable manual flush button

4 (if fitted)

= not used

manual flush button

 is hidden in the middle of the 

dolphin's body on the front of the unit. (see diagram 
overleaf)

5) Carefully 

connect battery

. A short press of the  "SET" button will flash red in the domed lens to 

show that the battery is sound and connected correctly.( see diagram over)  Plug in valve connector. 
Press manual flush button a few times to confirm operation of the valve, sharp click with red flash for 
"on", dull click with no flash for "off". 

Leave valve switched off

. N.B. As supplied, the valve might be 

latched open or closed, this is normal.
6) 

Turn on water

 supply, isolating valve/stopcock fully open. Smartflush is factory pre-set to activate 

maintenance flush

 at 12 hour intervals if no-one is seen.  

Go to step 7 if this setting is okay.

Hold down internal "SET" button, press and release the external hidden "MANUAL FLUSH" button, 
then release "SET" button. The red light flashes every 2 seconds; the number of flashes shows the 
current maintenance flush setting. Each press of "SET" button changes to the next setting, as 
follows :-

1 flash = No maintenance flush

2 flashes = 8 hour interval
3 flashes = 12 hour interval, (factory setting)
4 flashes = 24 hour interval

When desired setting is shown, press "MANUAL FLUSH" button to save setting and close the valve.