WIRE ATTACHMENT
SCREW
SENSOR
PROBE
OUTDOOR
INDOOR
WALL
Indoor/Outdoor Temperature Selection:
Both the indoor and outdoor temperature can be displayed in Celsius or Fahrenheit. The switch to select
between these settings is located in the back of the unit. Slide the switch to ˚C to display in Celsius and
˚F to display in Fahrenheit.
Note: If the temperature exceeds or falls below the measurable ranges, the LCD screen will display the
following letters:
HH.H
for temperatures above range and
LL.L
for temperatures below range. The
outdoor temperature display will also read
LL.L
if the detachable probe is not plugged into the jack.
Memory Function with Max./Min. Feature:
Press the “MEMORY ON/OFF” button to turn the memory function on (“MEM” will appear on the left
side of the display). The unit will begin to record the maximum and minimum indoor and outdoor
temperatures.
Press the MAX/MIN button once to display the maximum indoor and outdoor temperature readings.
When the maximum temperature readings are being displayed, MAX will appear in the lower-left
portion of the LCD window.
Press the MAX/MIN button a second time to display the minimum indoor and outdoor temperature
readings. When the minimum temperature readings are being displayed, MIN will appear in the lower-
left portion of the LCD window.
To return to the current temperature readings, press the MAX/MIN button again.
To clear the memory and exit the memory mode, press the “MEMORY ON/OFF” button again.
PRODUCT INSTALLATION
Choose a suitable place for the product and outdoor sensor. Place the unit near a window, but away
from direct sunlight or other sources of heat or air conditioning to ensure accurate air temperature
readings. The weather center can either stand upright or hang on a wall utilizing the nail/screw slot in
the back of the unit.
To Wall Mount Unit:
1.
Drive a screw into the wall at the desired location until the
head extends 1/8” from the wall.
2.
Position the slot at back of unit over the top of the screw
head and then slide down until the thermometer is locked
into place.
For accurate outdoor air temperature readings in summertime or
wintertime, the sensor should be placed approximately one inch
away from the house wall or windowpane using the metal wire
hanger enclosed.
To Mount External Sensor to Outside Wall:
1.
Drive a screw into the wall at the desired location.
2.
Route the external probe cable through a window.
3. Position the external probe into wire attachment.
For accurate outdoor air temperature readings in summertime or wintertime, the sensor should be placed
approximately one inch away from the house wall or windowpane using the metal wire hanger enclosed.