background image

Mains Pump Controller        Quick Start Guide

V11M BPC

Step 2. Set Up - Power Up and Filling

Step 2. Continued

This message will display if the PSU develops 

a fault. If voltage drops below 10.5V the unit will 

shut down the pump. 

Message

Description

If the unit is a 'One time 

ll' then pressing the up and down

arrows together and holding will stop the 

ll.

When the tank is full enough to activate the 

oat switch,

the controller stop the 

ll. The booster pump is stopped, 

the 

lling solenoid valve is closed. The controller will go

back to displaying the PSU voltage.

If your V11M is con

gured as a 'Fill on Demand' unit then

lling will start automatically as soon as the 

oat switch

is in the down (normally closed) position.

The controller will turn on the 

lling solenoid valve and the 

mains booster pump connected to the mains socket outlet.

This should allow water to 

ll your tank at a boosted

pressure by the mains booster pump.

On 

rst power up the controller displays the voltage of the

PSU in volts. It should be 12V (+/- 0.2V).

Turn on the controller by pressing the up or down button.

Keep the button held until the display lights up.

Connect your pump and liquid system to be controlled.

The controller is 

lling the tank. Booster pump

and solenoid 

lling valve are on.

If your V11M is con

gured as a 'One time 

ll' unit then

lling will start when you press and hold the up and down 

arrows at the same time.

+

+