background image

www.springusa.com 

Flush Mounting Your MAX Induction® Range: 

Remove your MAX Induction® range from the packaging and inspect all 
parts.  If the ceramic glass surface is cracked or damaged, do not install the 
range.  Contact your supplier for a replacement range. 

 

Counter or table thickness must not exceed 2”.  If installing multiple 
ranges, each range must be at least 4” apart. 

 

Your MAX Induction® Range must have the proper ventilation in order to 
operate correctly.  There must be at least 7” of space available under a 
mounted induction range.  Cabinets housing the induction ranges should 
have both vents & circulation fans installed.  The inside temperature of the 
cabinet must not exceed 90°F / 32°C. 

(1) 630-527-8600 

Install mounting bracket using (10) 
M5 x 18mm (furnished) wood screws 

Make range cutout through counter-
top and underlayment, using         
furnished template 

Place range into cutout and bracket 

 

 

Use the leveling screws to adjust the range height so that it rests flush with 
countertop 

 

Install (8) M5 x 45mm (furnished) 
leveling screws 

Fill in the seams using silicone sealant 

(1) 630-527-8600 

Countertop 

Range 

Underlayment 

Mounting Bracket 

Leveling Screw 

Reviews: