background image

Safety Precautions:

Plug the power cord into a dedicated circuit.  

Note:

Nothing else should be 

plugged into this circuit.  Each MAX Induction® Range must have its own, 
sufficient power supply as outlined below.  Once you have plugged the unit 
in, it will beep, and an ‘EO’ code will appear in the display window.

To Begin:

Turn the unit on.  An ‘EO’ code will appear next in the digital window, 
indicating the induction range is searching for cookware.

Turn the knob clockwise to turn the unit on.  Your MAX Induction® range 
will always start out in the “Cook” mode.  “Cook” is the default mode.

Place suitable cookware within the circle on top of  the MAX Induction®
Range. 

Select either the “Cook” Mode or the “Temp” Mode.

In “Cook” mode, turn the dial clockwise.  The LED will display cook 
power levels of 1 thru 20.

In “Temp” mode, turn the dial clockwise.  The LED will display 
temperature levels from 110° to 400° fahrenheit.

Turn the knob clockwise to set the power level or temperature.

To shut the induction range off, turn the knob counter clockwise until you 
hear the unit ‘click’ and turn off.

Actual range temperatures may vary due to a number of variables, such as 
ambient temperature in the immediate surrounding area, content and volume 
of food being heated or cooked, and whether or not you are using a lid on 
the serving vessel.  

-----------------

Never attempt to service any part of your MAX Induction® Range on your 
own.  Contact our Service Department by calling (1) 630-527-8600.  
Attempting to service your Induction Range on your own, or through an 
unauthorized repair facility automatically voids your warranty.  For service 
forms, visit the Spring USA website.

For Limited Warranty Information, visit 

www.springusa.com

Note:

This equipment uses, generates and can radiate radio frequency energy.  If 
not installed correctly and used in accordance with the instructions, may 
cause harmful interference to radio communications.  Users or guests with 
Pacemakers should contact their health care professional prior to using this 
product.

NEMA 6-20P        
6’ Cord

3500 Watts ~ 60 Hz

208-220 Volts / 15 Amps

SM-351C

CEE 7/7 16A
1.8 m Cord

3000 Watts ~ 50 Hz

220-240 Volts / 16 Amps

SM-353C

Plug Type

Peak Power

Voltage / Amps

Model #

Specifications:

Induction Range Error Codes:

www.springusa.com

(1) 630-527-8600

Review your dedicated power 
requirements. Each range must 
operate with the power required on 
Page 4.

Range will not turn on. Range is 
experiencing temporary voltage 
overload or is not on its own, 
dedicated circuit.

E3

Remove the cookware from the 
range and let the range cool. Make 
sure the vents are clear. Verify you 
are using induction-ready 
cookware. Once the range has 
cooled, restart.

The range has overheated.

E2

Clear vents, let range cool down, 
then restart.  If error message 
continues, your range needs to be 
serviced.

Range has overheated due to 
blocked ventilation and has shut 
down the range.

E1

Place an induction ready pan on 
the range.

Induction range does not sense 
induction-ready cookware has 
been placed on the glass surface

E0

Solution

Cause

Error 

4

5

All International Ranges ship with a CEE 7/7 16A plug.  International 
plugs must be changed to match the national standard, based on country 
requirement. 