background image

 

 

 

TROUBLESHOOTING 

Certain conditions could occur to cause a malfunction or unsatisfactory 

operation of the spray nozzle. These conditions are addressed in the table 

below: 
 

Problem 

Possible Cause 

Poor spray 

performance 

Clogged spray tip. Remove spray tip and clean orifice or 

replace tip. 

No fluid flow 

Clogged spray tip. Remove spray tip and clean orifice or 

replace tip. 

Debris in fluid passages. Disassemble nozzle and clean fluid 

passages.

 

Plunger not operational. Check coil for nominal resistance of 

67 Ohms. If open or shorted, replace nozzle.

 

Check fuse. If open, replace with 3/10 amp fast acting fuse.

 

No shut-off 

Debris in fluid passages. Disassemble nozzle and clean fluid 

passages. 

Broken spring. Disassemble nozzle and replace spring.

 

Worn seat. Disassemble nozzle and replace with  

AB10000AUH-03-Z1-EPFC spare parts kit.

 

 
 
 

 

Summary of Contents for PulsaJet 10000AUH-03-Z1-EPFC

Page 1: ...PulsaJet 10000AUH 03 Z1 EPFC USER GUIDE spray com MI 10000AUH 03 Z1 EPFC For Models AA10000AUH 03 Z1 EPFC NPT AAB10000AUH 03 Z1 EPFC BSPT EC 1935 2004 ...

Page 2: ...gned tasks US installations shall comply with the relevant requirements of the National Electrical Code ANSI NFPA 70 European installations shall comply with the relevant requirements of EN 60079 14 Make sure voltage supply is turned off to the installation before installing or maintaining the PulsaJet nozzle Do not disconnect live circuits when working with flammable materials Provide adequate ve...

Page 3: ... ethyl alcohol ethanol SPECIFICATIONS Power Requirements 27VDC Max 0 30 AMPS Max Inlet connections 1 8 NPT for AA10000AUH 03 Z1 EPFC 1 8 BSPT for AAB10000AUH 03 Z1 EPFC Electrical conduit connection 1 2 NPT for AA10000AUH 03 Z1 EPFC M12X1 5 for AAB10000AUH 03 Z1 EPFC Maximum Operating Pressure 100 psi 7 bar Maximum Flow rate 0 47 gpm 100 psi 1 8 lpm 7 bar Maximum Ambient Temperature 104 F 40 C Wei...

Page 4: ...nit ELECTRICAL CONNECTIONS Electrical conduit connection for conduit fitting accepts 1 2 NPT M for NPT version The conduit must protect the electrical cable from mechanical damage and terminate in a sealed enclosure or junction box appropriate for the hazardous location For BSPT version an Ex d rated cable gland is used with cable The fuse holder and a 3 10 amp fuse should be used as shown in Figu...

Page 5: ...tation using the threaded holes to mount to a bracket or other surface Alternately it may be supported by the inlet piping if rigid pipe is used Mounting holes inlet connections and outer dimensions are shown on Figure 2 FIGURE 2 OVERALL DIMENSION OF AA10000AUH 03 Z1 EPFC ...

Page 6: ...hich it is used FLUID SUPPLY Make sure maximum pressure rating of 100 psi 7 bar is not exceeded To help prevent clogging problems the fluid supply line needs to include a line strainer MAINTENANCE All power to the PulsaJet nozzle must be turned off before any maintenance is performed on the unit Overspray or other material should not be allowed to build up on the outside of the PulsaJet nozzle If ...

Page 7: ... spray tip Remove spray tip and clean orifice or replace tip Debris in fluid passages Disassemble nozzle and clean fluid passages Plunger not operational Check coil for nominal resistance of 67 Ohms If open or shorted replace nozzle Check fuse If open replace with 3 10 amp fast acting fuse No shut off Debris in fluid passages Disassemble nozzle and clean fluid passages Broken spring Disassemble no...

Page 8: ...s List for an exploded view and identification of numbered items FIGURE 3 AA10000AUH 03 Z1 EPFC EXPLODED VIEW Item Part No Description 1 CP1325 SS Retaining Cap Stainless Steel Type 303 2 AB10000AUH 03 Z1 EPFC Spare Part Kit Food Compliant Stainless Steel PEEK and EPDM 3 Nozzle Body Wetted parts are Food Compliant Stainless Steel EPDM and PPS ...

Page 9: ...9 RATINGS AND LABEL INFORMATION FIGURE 4A PULSAJET AA10000AUH 03 Z1 EPFC SPRAY NOZZLE LABEL NPT VERSION FIGURE 4B PULSAJET AAB10000AUH 03 Z1 EPFC SPRAY NOZZLE LABEL BSPT VERSION ...

Page 10: ...79 1 EN 60079 18 FM10ATEX0040X1 The Electromagnetic Compatibility Directive 2014 30 EU of 26 February 2014 EN 61000 6 4 EN 61000 6 2 N A As per Article 14 and Annex II and III of 2014 30 EU a technical construction file was developed and is available to competent authorities upon request The analysis tests and measurements were performed according to Harmonized Standards 1 Certificate issued by FM...

Page 11: ...Spraying Systems Co part number listed above All stainless steel components are in accordance with European Standard EN10088 as well as guidelines for 300 series and 430 series stainless steel as offered by the Federal Food and Drug Administration using AISI guidelines Plastic components gaskets seals and O rings follow either EU Directive No 10 2011 including all amendments and or certified under...