40
12.10 LASER SENSOR (SHORT)
For accurate short distance sensing of objects (thin, shiny, dark, clear, multi
-
faceted)
SPECIFICATIONS:
Laser sensor –
with cable, connector, and bracket.
•
Kit number: 040TS04000135W0
•
NPN –
NO + NC
•
1.0”
–
3.5”
[25mm –
90mm] sensing range (1.5mm –
3mm deviation range).
•
Working temperature range = 10°F to 122°F [
-
10°C to 50°C]
•
IP69K, NEMA 4X; CE rated
•
Mounting bracket, accurate short sensing distances of 25 to 90 mm, std. detectable deviation 1.5
-
3.0mm, NPN/PNP open collector, 24Vdc, M12 4 pin male connection, 5m cable.
12.11 LASER SENSOR (LONG)
For accurate long
-
distance sensing of objects (shiny, dark, clear, multi
-
faceted)
SPECIFICATIONS:
Laser sensor –
with cable, connector, and bracket.
•
Kit number: 040TS04000087W0
•
NPN –
NO + NC
•
1.38”
–
19.69”
[35mm –
500mm] sensing range (9mm –
50mm deviation range).
•
Working temperature range = 10°F to 122°F [
-
10°C to 50°C]
•
IP69K, NEMA 4X; CE rated
•
5m cable, and mounting bracket, 24Vdc, NPN. IP68/ IP69K.
12.12 FAULT OUTPUT SIGNAL
The SCS Series spray control panels offer a feature to signal your system when a fault has occurred in the operation of
the spray control panel (for example a level sensor going low or a short in one of the nozzle cables). To use this fea-
ture, you need to have our optional splitter cable kit.
Wire the fault output to any 24VDC buzzer, light, or PLC. You will need the splitter and the extra cable shown below.
•
Kit 040TS04000054W0 includes both parts.
This end goes in the Main connector on the 1750+ panel. The black and the white wires from the flying leads cable
get wired to your PLC or light or buzzer, snip the blue and brown wires, they are not used. Fault cable pinout below:
If any electric nozzles are used, they get hooked up to the open M12 connector on the wye connector.
•
Panel connection: Main
•
Cable: M12 4 pin (M) x Flying Leads
-
16.4 ft. [5 m] (Connects to one connector on splitter), flying leads (Part
number: LE00M12M5M)
The flying leads from cable of the kit are to be connected to the customer
’
s PLC or warning signal light,
+24VDC. (black and white wires)
•
Adapter: Splitter –
M12 (M) x 2 M12 (F)
-
3 ft. [1 m] whip
cord length (Part number: LE00M12WYE1M)
•
Open connector on splitter
Connect PulsaJet cable; AA250 cable; or extension
cable to this connection.