15.

 

Thread 

Inlet 

and Outlet Adapters (3) and (27) 

until the 

flats are 

properly 

aligned with the 

flats 

in 

the Housing Half 

(1).

 

16.

 

Follow trigger 

lock 

adjustment procedure 

from 

step 3 

throu

g

h 11 

as 

described 

below.

 

TRIGGER LOCK ADJUSTMENT PROCEDURE:   

Under no circumstances should this spray gun be operated with a incorrectly 

adjusted Trigger Lock. The Trigger Lock operation should be checked before 

each spray period and after each disassembly. It operates properly when it 

locks the Trigger tightly in the "Off" posit ion after the Trigger lock is rotated to 

its "Locked" position. However, if the Trigger is not tight or can move while in 

this “Locked" position, adjust the Trigger Lock as follows: 
1.

 

Disassemble Left-Hand and Right-Hand Housings (1) by removing the 7 

Screws (2). 

2.

 

Loosen Stem Nut (23) while using 1/2" wrench to keep Trigger Guide 

(17) from turning. 

3.

 

Rotate Trigger Lock (25) until locking lugs are positioned as shown in 

Parts List PL80 where knurled side of thumb wheel is closest to the 

Stem Nut (23) (Trigger in locked position). 

4.

 

Holding Trigger (20) firmly against lugs of Trigger Lock (25), tighten 

Trigger Guide (17) against back surface of Trigger (20). 

5.

 

Turn Trigger Guide (17) one-half turn away from the Trigger (20) and 

securely tighten Stem Nut (23) against Trigger Guide (17) while using a 

1/2" open end wrench to keep Trigger Guide (17) from turning. 

6.

 

Check to ensure that the Trigger (20) does not contact the  

Trigger Guide. 

7.

 

(17) when the Trigger Lock (25) is in the lock position. (Repeat above 

steps 3 through 6 of necessary.) 

8.

 

Carefully and cautiously check for leakage at all joints. 

9.

 

Release all pressure and correct any detected leakage. 

10.

 

Reassemble Housing Halves (1) and install 7 Screws (2). 

11.

 

CAUTION: Do not over tighten screws. 

12.

 

Be sure Trigger Lock is in the locked position before attaching to 

pump. 

Summary of Contents for GunJet 80

Page 1: ...80 80W High Pressure GunJet Spray Gun USER GUIDE spray com MI 80...

Page 2: ...OPERLY ENGINEERED SYSTEM THIS SPRAY GUN SHOULD BE OPERATED ONLY BY TRAINED OPERATORS AND KEPT OUT OF REACH OF CHILDREN PLEASE READ THE FOLLOWING INSTRUCTION SHEETS BEFORE ATTEMPTING TO OPERATE THE 80...

Page 3: ...st rated accessory item within the spray system even though some of the accessories have a higher maximum pressure rating 5 DO NOT leave equipment under pressure unattended at any time Relieve pressur...

Page 4: ...efore attempting to remove the tip nozzle gun or any part of the gun or when gun is not in use 5 DO check operation of Trigger Lock before each spray period Trigger Lock must hold the Trigger to its f...

Page 5: ...ld be used 3 Follow your pump and component parts manufacturer s recommendations for operation but in any case do not exceed the pressure or temperature of the lowest rated component within the system...

Page 6: ...25 and Outlet Tube 24 7 Remove Stem Nut 23 Spring 22 and Washer 21 while using a 1 2 wrench to keep Trigger Guide 17 from turning 8 Remove Screw 19 Screw Housing 18 Trigger 20 and Trigger Guide 17 to...

Page 7: ...ded section of Stem Assembly 8 9 10 11 until it engages the unthreaded section of the Stem 10 8 Slide Stem Assembly 8 9 10 with Seat Retainer Assembly 11 12 and Packing Screw 16 into Inlet Body 5 9 Th...

Page 8: ...1 2 wrench to keep Trigger Guide 17 from turning 3 Rotate Trigger Lock 25 until locking lugs are positioned as shown in Parts List PL80 where knurled side of thumb wheel is closest to the Stem Nut 23...

Page 9: ...9 DATA SHEET...

Page 10: ...10 PARTS LIST...

Page 11: ...11...

Page 12: ...12 North Avenue and Schmale Road P O Box 7900 Wheaton IL 60187 7901 Tel 1 800 95 SPRAY Intl Tel 1 630 665 5000 Fax 1 888 95 SPRAY Intl Fax 1 630 260 0842 www spray com MI 80 Spraying Systems Co 2019...

Reviews: