6
3.2 SYSTEM SPECIFICATIONS
The AccuCoat® MV10 Heated Spray System is powered by 230 VAC 1 ø. The main air supply is connected to the sys-
tem via
1/4”
NPT (F) located on the tank.
Panel Power:
/
-
15% 1 ø, 60Hz, 25A max (Plug in a grounded GFCI outlet)
Air Input:
•
Pressure: 80 psi (min), 115 psi (max)
•
Inlet Port: Tank:
1/4”
NPT (F)
•
Consumption: Main System: 5 SCFM maximum
Environmental
•
Operating temperature range: 32°F to 109°F (0°C to 42.8°C)
•
Humidity Range: 5 to 95% (non
-
condensing)
•
Enclosures: NEMA 4
•
Weight: Control Panel/tank skid
-
360lb (empty)
•
Dimensions:
58”
H x
45”
L x
35”
D
Level Switches
•
TDR (Time Domain Reflectometry) Level Sensor
•
-
4°F to 302°F (
-
20°C to 150°C), 232 psi max. (16 bar), 24 V DC
•
High Frequency Capacitive Level Switch (stand pipe)
•
185°F max. (85°C) continuous, 302°F short time (150°C)
Pressure Tank
•
10 gal, Jacketed, Insulated
•
304 SS construction Electropolished
•
40psi max jacket
•
100psi max tank
•
300°F max
Centrifugal Pump
•
1/3 hp 230VAC 1 ø
Immersion Heater
•
304 SS screw plug, Stainless steel heating element, safety shut off
•
70°F
-
200°F ( 21°C
-
93°C) range, 3KW, 230VAC 1 ø