background image

Step 1

 

Mount the radar. See provided 

Quickstart Guide 

SP-Mount-1 or SP-Mount-RINO

  for details on mounting 

and install practices. Be aware some models require 

specific orientation for installation as indicated by 

orientation stickers.

 

Step 3b

 

GTC Connector instructions Once the 

cable has been tested and is ready for final installation, 

fill Radar GTC connector with dielectric grease. Ensure 

each contact/pin is heavily covered. (Fig. 3) 

Step 4b

 

Coat contacts/pins on incoming RJ45 with 

dielectric grease and connect RJ45 to GTC connector 

on radar. (Fig. 4)

Warning: 

Do not apply grease until ready for final 

connection. A contaminated connection can cause failure. 

DO NOT USE GREASE ON PQT CONNECTIONS!

Fig. 3

WARNING

: ALL CABLES USED MUST BE OUTDOOR RATED, CAT5E, AND SHIELDED

Step 6

 

Power PoE injector and connect network 

to the radar. If using a SpotterRF power kit, 

connect to the port labelled “Network” in the 

diagrams to the right. 

(If using an Integrated 

Control Cabinet, see Cabinet quickstart for 

Network Port locations.)

Fig. 4

Step 2

 

 Before connecting the Radar to PoE, ensure the 

Ethernet Cable being used is tested for continuity to ground, 

network connection, and power consumption. 

(See Quickstart Guide SP-TESTKIT or Youtube video for 

testing instructions, QR Code and Link found on the next 

page for tutorial.)

Radar

Network

Network

Radar

Step 7

 

To access the radar UI, connect a computer 

via ethernet to the Network Port. Set your PC to “Obtain 

Automatically” IP settings or DHCP. 

The UI can be accessed by entering 169.254.254.254 

into a web browser. Google Chrome and Firefox are 

recommended.

169.254.254.254 is the default IP address for all radars. 

When using the default address, ensure that the 

computer is set to DHCP and only one radar is 

connected.  Otherwise, there may be a network conflict 

between radars.

Step 5

 

Connect radar ethernet to PoE. If using a 

SpotterRF power kit, see diagrams to the right. Connect 

to the port labelled “Radar”. 

(If using an Integrated 

Control Cabinet, refer to the cabinet quickstart for PoE 

port locations.)

 

Wire without 

writing is (+) for 

PoE Injector

Wire without 

writing is (+)

for PoE Injector

Quickstart Guide - SpotterRF Radar

SP-POWER-1

SP-POWER-4

Fig. 1

Fig. 2

Step 3a

 

 PQT Connector instructions:  The PQT is not 

field serviceable (Fig. 1). To adjust cable length, do so by 

cutting off the RJ45 end to the correct length and recrimping 

a new end. RJ45 to RJ45 waterproof coupler supplied to 

support longer cable lengths.

Step 4a

 

Connect to radar by aligning indexing pins 

correctly (Fig. 2), push in connector, rotate locking ring 

clockwise until seal connection locks.

04/07/20  REV 003

CK2B-CE

Reviews: