Profile LED Hyperion 300 6C
17
OPERATING MODE
The luminaire is designed to be used in different
operating modes:
• LOCAL POTENTIOMETER
• DMX (Wireless optional)
• RDM
• STAND ALONE
LIGHT OUTPUT CONTROL DEPENDING ON THE
TEMPERATURE
The fi xture is equipped with a temperature
control of the LED and of the driver motherboard,
which, to avoid an early deterioration in case of
overtemperature, regulates the light intensity.
INPUTS PRIORITIES
Input priority is given:
-
in absence of the DMX signal,
the value set with
the potentiometer will be active
-
when there is the DMX signal
the relevant signal
is followed and the potentiometer will be ignored
-
if the DMX signal is eliminated or lost
, the
DMX set level is kept until you act on the
potentiometer, which will set the new value.
DISPLAY INTERFACE
MENU
When switched on, the installed software version
is displayed, followed by the display of the default
settings, ie the currently set operating mode.
If the luminaire is DMX controlled, after 3 seconds
the display will show the mode and DMX address
Otherwise it will show the potentiometers status:
Should the luminaire be set in one of the standalone
modes (please see the relevant paragraph), the display
will show one of the following info:
*DMX LINE BUSY will appear only when the dmx line is
busy with the consequent impossibility of producing a
DMX signal on the line.
SETUP
RGBACL 8bit - 9CH
001
SETUP
MANUAL
GREEN
18%
SETUP
STANDALONE
MANUAL
SETUP
STANDALONE
AUTOSCENE
1/5
SETUP
MASTER
MANUAL
DMX LINE BUSY *
SETUP
SLAVE
SETUP
MASTER
AUTO SCENE
1/5
DMX LINE BUSY *