Sportsman GEN2000LP Instruction Manual Download Page 19

GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual 

 

 

19

 

 

MAINTENANCE/CARE 

 

Proper routine maintenance of this generator is essential for safe, economical, and trouble-free operation. It will help prolong the life of this generator 
as well as help reduce air pollution. Perform maintenance checks and procedures according to the schedule in Figure 10. 

 

STOP!

 

If you have questions about maintenance procedures described in this manual, call 1-866-460-9436 , Monday - Friday, 8 AM - 4 PM Central Time. 
 
                                                                                                  

 

Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance 

procedures. Keep heat, sparks and flame away. 
 

                                                                                                 

 

Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction which could cause 

death or serious injury. Always follow the inspection and maintenance recommendations and schedules in this manual. 
 

Recommended Maintenance Schedule 

 

 

 

Each Use 

Every Month or 
Each 20 Hrs 

Every 3 Months or 
Each 50 Hrs 

Every 6 Months or 
Each 100 Hrs 

Every Year or 
Each 300 Hrs 

Engine Oil 

Check Level 

 

 

 

 

 Replace  

X (First Use) 

 

 

Air Filter 

Check 

 

 

 

 

 Clean     

 

 

Spark Plug 

Check/Clean 

 

 

 

 

 Clean      

  

Figure 10 - Recommended maintenance schedule 

 

 

Cleaning the Generator 

 

Always try to use this generator in a cool dry place. If this generator becomes dirty, the exterior can be cleaned with a damp cloth, soft brush, 

vacuum and/or pressurized air. 

 
Never clean this generator with a bucket of water and/or a hose as water can get inside and cause a short circuit or corrosion. 

 

Never use gasoline to clean parts of this generator. 

 
 

Checking the Oil Level 

 
Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil, it is important to check the oil level in the 

engine crankcase before each use to ensure that there is a sufficient quantity. 

 

To check the oil level: 
1. Verify that this generator is shut down and on a level surface. 

2. Unscrew the oil filler/dipstick cap from the engine as illustrated in Figure 11. 

3. With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap. 

4. Insert the dipstick as if replacing the cap and then remove again. There should be oil on the dipstick. If there is no oil on the dipstick, or oil is 

visible only at the very end of the dipstick, add oil until the engine crankcase is filled (see “Changing/Adding Oil” in this section of this manual). 

5. Confirm that the oil filler/dipstick cap is properly in place when finished verifying the oil level. 
 

Summary of Contents for GEN2000LP

Page 1: ...is product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS PRODUCT TO THE RETAILER CONTACT CUSTOMER SERV...

Page 2: ...this warranty DO NOT RETURN TO RETAILER Instead call Customer Service toll free at 1 866 460 9436 email address info buffalotools com and you will be instructed on where to take the engine for warran...

Page 3: ...Step 3 Ground The Generator 14 Subsequent Use Of This Generator 14 Step 1 Verify Oil Level 14 Step 3 Ground The Generator 15 STARTING THE GENERATOR 15 USING THE GENERATOR 16 AC Usage 16 DC Usage 18 ST...

Page 4: ...rstand This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates...

Page 5: ...o an explosion even if not directly in contact the fuel Do not operate this generator near open flame Always operate this generator on a firm level surface This fuel is highly flammable and explosive...

Page 6: ...city of this generator Do not turn on electrical devices until after they are connected to this generator Turn off all connected electrical devices before stopping this generator Usage Consult a physi...

Page 7: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 7...

Page 8: ...000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this gener...

Page 9: ...tts 1350 Running Watts Portable LP Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RET...

Page 10: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 10 GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator...

Page 11: ...r can damage your generator and your electrical devices and will void your warranty To prevent electrical shock from faulty appliances the generator should be grounded Connect a length of heavy wire b...

Page 12: ...correct quantity of oil is equal to the oil capacity of the engine crankcase and is 14 fluid oz for this model GEN2000LP 2000 Surge Watts 1350 Running Watts Portable LP Generator Add the correct quan...

Page 13: ...ints should be tightly secured before operating the machine Check the joints and gas hose for leakage or breaks replace the damaged joints and hose if necessary Check the gas pipeline for any damages...

Page 14: ...fy Oil Level Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil it is important to check the oil level in the engine crankcase before each use to...

Page 15: ...en correctly completed If unsure about how to perform any of these steps call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service Disconnect all electrical loads from this generat...

Page 16: ...less than or equal to the rated wattage for the generator i e no more than 2000 for this Model GEN2000 2000 Surge Watts 1350 Running Watts Portable Generator This generator can run at its surge wattag...

Page 17: ...Figure 8 for an illustration of these outlets Even though this Model GEN2000LP Portable LP Generator has an overall rated wattage of 2000 do not attempt to draw more than 1350 Watts 20 A from any ONE...

Page 18: ...the positive terminal of the battery and the black charging wire to the negative terminal of the battery 2 Connect the plug end of the wire to the 12V DC outlet on this generator 3 Start this generat...

Page 19: ...ark Plug Check Clean X Clean X Figure 10 Recommended maintenance schedule Cleaning the Generator Always try to use this generator in a cool dry place If this generator becomes dirty the exterior can b...

Page 20: ...d on the crankcase underneath the oil filler dipstick cap as illustrated in Figure 12 3 Allow all the oil to drain from this generator 4 Replace the oil drain plug and tighten with a 10 mm hex wrench...

Page 21: ...sh the sponge like elements in household detergent and warm water Do not use gasoline or a flammable solvent 5 Allow the sponge like elements to dry thoroughly 6 Soak the dry sponge like elements in e...

Page 22: ...e moving it A hot engine and exhaust system can burn you and ignite some materials Disconnect the battery used for the electric start feature of this generator first disconnecting the black cable and...

Page 23: ...ices Disconnect any faulty or short circuited electrical loads Generator runs but does not support all connected electrical devices Air filter is dirty Clean or replace air filter Loose wiring harness...

Page 24: ...Wattage W 2000 Surge Wattage W 1350 Rated Voltage V 120 Rated Amperage 9A at 120 V Rated Frequency Hz 60 Phase Single DC Output Voltage V 12 Circuit Breaker Amperage A 10 Engine Approvals EPA Engine...

Page 25: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 25 PARTS DIAGRAM...

Page 26: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 26 PARTS DIAGRAM...

Page 27: ...GEN2000LP 2000 Surge Watt 1350 Running Watt Portable LP Generator Manual 27 201109...

Reviews: