![SportsArt Fitness E875 Repair Manual Download Page 24](http://html1.mh-extra.com/html/sportsart-fitness/e875/e875_repair-manual_1350345024.webp)
Troubleshooting
Model no. E875
Malfunction item: Bad telemetry heart rate reception
Circumstance: Bad telemetry heart rate reception
Possible causes:
1.Telemetry transmitter battery too low
2. Bad HR receiver board
3. Interference issue, such as lights, speakers
Troubleshooting: 1.Replace the transmitter or its battery
2. Check HR receiver board wiring
3. Replace the receiver board
3-4-1
Polar
Receiver
Display
board
Transmitter
Wireless HR board
Polar T34
Summary of Contents for E875
Page 1: ...E875 Repair manual Electronics...
Page 2: ...1 1 Product E875 1 1 1...
Page 3: ...1 2 Display E875 1 2 1...
Page 4: ...1 3 Component placement E875 Display 1 3 1 Control board Program board...
Page 8: ...1 5 Wiring diagram E875 1 5 1...
Page 13: ...1 6 LED indicator E875 Display 1 6 1 POWER1 LED2communication indicator...