Data Sheet Includes Information On

Splendide

Product Model Number

WDC6200CEE - (LD)

Comb-o-matic 6200 Laundry Center

Installation Location:
· Unit may be installed in recessed area,                            
  closet, or alcove. 
· Air Space Requirements: 0" on sides and  
  1" in front and back (from the case).  
   Additional installation spacing needs to be  
  considered for easy installation, servicing,  
  and compliance with state and federal  
  codes.
· Floor must support at least 280 lbs. and be     
  a solid, level surface.
· When locating in a towable trailer or      
  watercraft, position the machine over      
  the axles or mid-ship where movement is      
  at a minimum. Block unit in to prevent      
  extreme movement. 
  
Electrical Requirements:
· Machine Voltage/Amperage:  120V, 13 Amp,  
  60 Hz.
· Connection:  3-prong plug with 6' cord is      
  provided with unit.
· Circuit/Protector: 3-wire single phase, 120V,    
  60Hz, AC, on separate 15 Amp circuit.

Standpipe Drain System/ Sink Draining 
Requirements:
· Needs a 1 ¼" (3.2 cm) minimum diameter            
  standpipe with the minimum carry-away      
  capacity of 7 gallons (26 liters) per minute.      
  Top of standpipe must be at least 25" (62      
  cm) high and no higher than 34" (86 cm)      
  from the bottom of the washer.  
· Outlet end of drain hose (provided with the     
  unit) must be at least 20" above bottom of     
  washer.  An air break must be available at      
  the standpipe to avoid siphoning.

· Faucet Adapter Kit #154187104A is      

  available to allow for direct faucet      
connection.  See complete installation      
instruction on drain hose draining directly      
into sink, connection to dishwasher Wye      
fitting, and disposer/drain connection in       
owners manual.

· Optional Drain-A-Way™ Pans are    
  available.  Pan #PI-24 for cabinet or under-
  counter installations. Pan #P-24 for free-  
  standing installations.  Both are designed to  
  be drain plumbed.

NO DRYER VENT REQUIREMENTS ON 
THIS MACHINE:
· This machine incorporates an internal      
  condenser for drying.  All humidity stays      
  within the unit and is drained as water.  No     
  heated or air conditioned air is exhausted      
  outside, so no vent is needed.  This not      
  only conserves energy, but also avoids      
  problems with the delicate air balance      
  requirements in large multifamily       
  complexes.

Never reuse data sheets.  Data sheets are subject to change without notice.  Never use data sheets for final installation criteria.  Complete 

installation instructions are available upon request and in the owner's manual that comes with the unit.

23-7/16"

Water Inlets

Electrical Cord Location

6' cord length

H

C

Control Panel

depending on 
positioning of 
leveling legs

Drain Outlet

6"

Plastic 
U-Clamp

Flexible 
Drain Hose

(5' length)

Side View (not to scale)

NOTE: Electrical Cord Location, Drain Outlet, and Water Inlets are located on the rear of the unit

Front Leveling

Legs

21-3/16" 

total case depth

22-7/8"

 total depth including

top overhang and door handle

NOTE:  24" minimum width entry doors and hallways recommended for ease of installation. 

11/16"

34-11/16"

21-1/16"

2-1/4"

4-3/4"

1-3/8"

29-3/4"

2-1/2"

29-1/2"

2-1/2"

33-1/8" 

to

 33-1/2"

Front View (not to scale)

1-1/2"