Spitwater 10-120H Operating And Maintenance Manual Download Page 6

 

 6 

 
 

1.  OBSERVE SAFETY INSTRUCTIONS 

  Make sure you have read and understood the whole instruction 

manual before installing, operating or carrying out any maintenance 
on this unit. 

  Warnings and serial label on the unit provide important directions 

and information on the safe use of the unit. 

  In addition to these operating and safety instructions please make 

sure that all accident prevention regulations applicable in the 
country of use are followed. 

  In addition to these operating and safety instructions any standards relating to the installation and 

operation of high pressure cleaners applicable in your country must be strictly followed. 

  This unit is not intended for use by children. Children must always be supervised when in the 

vicinity and ensure that they DO NOT play with the unit. Further, it is not intended for use by 
persons with reduced physical, sensory or mental capabilities, or lack of experience or 
knowledge. It must only be operated by persons instructed in its use who have been especially 
authorized to do so. 

  DO NOT operate the unit without appropriate personal protective equipment PPE. 

 

2.  ELECTRICAL CONNECTION 

  The voltage, hertz rating and number of phases on the serial label 

must correspond to that of the electrical mains outlet. 

  Only connect the unit to electrical installation made by 

certified 

electrician and comply with IEC 60364-1.

 

  It is recommended that the electrical supply to this unit should 

include either a residual current device that will interrupt the 
supply if the leakage current to earth 

exceeds 30mA for 30 ms

 or 

a device that will prove the earth circuit. 

  Switching on the unit may cause voltage fluctuations. Voltage 

fluctuations should not occur if the impedance of the transfer point 
is less than 0.15Ω. If in doubt contact your power supplier. 

  This Class 1 Appliance must only be connected to an earthed 

power supply fitted with an appropriately sized fuse. 

 

3.  POWER CORD 

  Make sure before every use that the power cord assembly is not 

damaged or cut. If it is DO NOT connect the unit, have it replaced 
by an electrician or authorized service technician. 

(Type Y 

attachment)

 

  DO NOT pull on the power cord in order to unplug the unit, 

remove the plug from the power outlet.

 

 

 
 
 
 
 
 
 

GENERAL SAFETY PRECAUTIONS 

 

 

 

 

 

 

 

30mA

 

 

 

 

Summary of Contents for 10-120H

Page 1: ...rstand this instruction manual before operating this unit and retain for future reference Failure to follow operating safety and maintenance instructions outlined in this manual releases the manufactu...

Page 2: ...ccordance with the recommendations and safety precautions detailed in this manual All Spitwater high pressure cleaners undergo rigorous safety and operational tests before being dispatched into the ma...

Page 3: ...P PUMP MODEL WW186 WW95 N A N A N A OIL TYPE 15W 40 15W 40 OIL CAPACITY 0 4 0 3 L OTHER DETERGENT BOTTLE CAPACITY 1 5 N A L BURNER PRESSURE 9 9 BAR VALUES DETERMINED AS PER AS NZS 60335 2 79 SOUND PRE...

Page 4: ...meaning is listed next to them for your attention CAUTION Hot surface Do not touch DESCRIPTION OF SYMBOLS IMPORTANT SAFETY INSTRUCTIONS AND PRECAUTIONS WARNING This high pressure cleaner shall only be...

Page 5: ...lter or remove safety labels TRIGGER GUN HIGH PRESSURE HOSE HIGH PRESSURE WATER OUTLET CONNECTOR DIESEL INLET BURNER SWITCH TEMPERATURE ADJUSTMENT DUAL LANCE PRESSURE GAUGE POWER PLUG UNIT ON OFF SWIT...

Page 6: ...do so DO NOT operate the unit without appropriate personal protective equipment PPE 2 ELECTRICAL CONNECTION The voltage hertz rating and number of phases on the serial label must correspond to that o...

Page 7: ...pe 6 FIRE PREVENTION AND HOT SURFACE CAUTION Store flammable fluids in approved containers and cabinets away from sparks and heat To avoid fire be alert for leaks of flammable substances from hoses an...

Page 8: ...ergent or oil follow instructions provided by the manufacturer and or product retailer and wash it off immediately with clean running water Wear rubber gloves to avoid personal injury during chemical...

Page 9: ...user is subject to very strong recoil forces and torque There is a risk of high pressure water jet injury Never aim the jet at yourself other people or animals as this could result in serious injuries...

Page 10: ...are parts that were not designed for use with this unit as this could cause damage to the unit Spitwater recommends the use of original accessories and spare parts available through Spitwater and its...

Page 11: ...ansporting the unit make sure there is no possibility for the temperature to be at or below 0 C If it is necessary to transport the unit at or below 0 C contact your authorized Spitwater service agent...

Page 12: ...e note that incorrect voltage or insufficient power supply will cause immediate damage to the unit ASSEMBLY INSTALLATION GUIDE Note Any work needed on initial installation to connect the unit to the p...

Page 13: ...do not interchange during assembly Add nozzle shield after nozzle assembly Refer diagram below 9 LANCE TRIGGER GUN HIGH PRESSURE HOSE ASSEMBLY Connect the lance to the spray gun by an in built quick r...

Page 14: ...agent if found Open the water supply and fill the water tank The float valve will automatically stop the water flow when the water tank is full Water that has flowed through backflow preventer is con...

Page 15: ...15 12 Remove the DIESEL tank cap and fill the diesel tank with clean filtered diesel ONLY USE CLEAN DIESEL IN THIS UNIT as using any other fuel will create a risk of explosion and damage to the unit...

Page 16: ...to expel Note If this is the first use of the unit or the unit has been left idle for an extended period of time it is advisable to run this operation with the front part of the lance disconnected in...

Page 17: ...temperature 3 After hot water use turn burner switch in anti clockwise to turn OFF the hot water and change back to cold water mode for cleaning 1 To activate high pressure turn the lance handle clock...

Page 18: ...until the desired affect is reached When the trigger is pulled water mixed with detergent will be sprayed 4 Never allow sprayed detergent to dry on the cleaning surface as this may damage the surface...

Page 19: ...ents that have been set and sealed at the factory Never under any circumstances tamper with modify or adjust these settings 7 Make sure this unit is regularly serviced by an authorized Spitwater servi...

Page 20: ...appearance Check for any service due based on USAGE VS SERVICE FREQUENCY Table A Proper function of burner switch temperature controller and pressure gauge Check for water leaks at high pressure hose...

Page 21: ...r units subjected to normal operating conditions Should the unit be subjected to abnormal conditions e g heavy use dirty water extreme temperatures or conditions etc times should be reduced accordingl...

Page 22: ...he oil level in the pump using the dipstick or the sight glass on the back side of the pump Make sure the level is between min max level notches on the dipstick or is level with the indicator on the s...

Page 23: ...off is activated Check that water diesel tank are full and add water diesel as necessary No power supply Contact an authorized electrician to check power supply When switch is activated the motor hum...