1.  Remove the foam from the console mast axles and the plastic ties from the tubes that slide onto the console 

mast axles.

2.  Slide the two swing arms (

8

 Right & 

9

 Left) onto the console mast axle. There is a left and right swing arm 

(marked with an “R” and an “L”) so make sure you assemble the correct one on each side. Do not force the 
arms onto the axle or use a hammer, as damage to the bearings could occur. The swing arms have been  
previously installed at the factory and should fit properly, although it is a snug fit.

3.  Secure the swing arms in place with the stainless steel bolts (

40

; flat side of washers should be on the outside) 

and cup washers (

24

) and tighten with the wrench (

108

). Snap the decorative caps (

67

) over the cup washers.

4.  Install the foot pedals (

72

 Left & 

73

 Right) with eight Phillips head screws (

45

) and tighten with the Phillips 

head screw driver (

107

). The pedals are identified with an L or R on the bottom.

HARDWARE

STEP 2:

 Swing Arms & Pedals

#24. 

Cup Washer

(2 pcs) 

#40. 

M8 x 15mm

Stainless Steel Bolt

(2 pcs)

#45. 

M5 x 10mm

Phillips Screw

(8 pcs)

Summary of Contents for Glide Trainer

Page 1: ...Please carefully read this entire manual before operating your new e Glide Trainer OWNER S MANUAL e Glide Trainer XG200...

Page 2: ......

Page 3: ...t Electrical Instructions XG200 Assembly Instructions Operation of Y our Console General Maintenance Manufacturer s Limited Warranty ATTENTION This e GlideTrainer is intended for residential use only...

Page 4: ...2 e Glide Trainer XG200...

Page 5: ...nt as possible for many years to come If not purchased direct from Spirit Fitness the local dealership where you purchased this e GlideTrainer is your administrator for all Spirit Fitness warranty and...

Page 6: ...e GlideTrainer is not working properly call your dealer Keep the cord away from heated surfaces Do not operate where aerosol spray products are being used or where oxygen is being administered Sparks...

Page 7: ...perate this e GlideTrainer without reading and completely understanding the results of any operational change you request from the computer Understand that changes in resistance do not occur immediate...

Page 8: ...parts are found or parts are missing contact your dealer immediately 3 Locate the hardware package The hardware is separated into four steps Remove the tools first Remove the hardware for each step as...

Page 9: ...ng the 8mm Allen wrench 108 5 Attach the hand brake lever 90 to the handlebars as follows HARDWARE STEP1 Console Mast 42 M10 x 20mm Stainless Steel Bolt 4 pcs 50 M10 Split Washer 4 pcs Remove the scre...

Page 10: ...ng arms have been previously installed at the factory and should fit properly although it is a snug fit 3 Secure the swing arms in place with the stainless steel bolts 40 flat side of washers should b...

Page 11: ...the wrenches provided 110 111 Over tightening the hardware won t allow the wheels to rotate 2 Remove the cover on the back of the console and install the 4 C batteries 3 Snap the four end caps 67 ont...

Page 12: ...ackets at the bottom of the swing arms to the pedal arms using a shoulder bolt 55 and a nut 56 on each side Tighten securely with the wrenches provided 109 116 HARDWARE STEP4 Arm Connection 55 M10 x 2...

Page 13: ...front and rear levelers all the way in then back them out about two or three turns Level the unit using only the front and rear levelers first then adjust the middle levelers so they touch the floor...

Page 14: ...t the console will power on theTime window will display an hour meter reading the Level Distance window will display an odometer reading and the RPM Speed window will display the software version The...

Page 15: ...he down key will decrease the time setting by 1 minute for each key press The time will change more rapidly when the key is held down for 2 seconds After the start key has been pressed pressing the ke...

Page 16: ...General Maintenance To enter the management mode press the START STOP key until the console resets During the reset while the LCD segments are all lit hold down the START STOP and keys until theTime...

Page 17: ...ifications abuse misuse accident improper maintenance inadequate power supply or acts of God 4 Products with original serial numbers that have been removed or altered 5 Products that have been sold tr...

Page 18: ...www spiritfitness com 2601 Commerce Drive Jonesboro AR 72401 Phone 800 258 4555 Fax 870 935 7611 2011 All Rights Reserved XG200 Owner s Manual 1 1 Rev 1...

Reviews: