background image

© 2014 i-SENS, Inc. All Rights Reserved     PGC8E3024 REV0 03/2014

Medical Technology Promedt 
Consulting GmbH, Altenhofstrasse 80, 
D-66386 St. Ingbert, Germany

i-SENS, Inc.

27-36, Gwangun-ro, Nowon-gu
Seoul 139-845, Korea
www.i-sens.com

Spirit Healthcare Ltd.

Spirit House, Selbury Drive, Oadby, 

Leicester, LE2 5NG

Customer Support Tel : 0800 881 5423

www.spirit-healthcare.co.uk

®

®

Summary of Contents for CareSens N

Page 1: ...Promedt Consulting GmbH Altenhofstrasse 80 D 66386 St Ingbert Germany i SENS Inc 27 36 Gwangun ro Nowon gu Seoul 139 845 Korea www i sens com Spirit Healthcare Ltd Spirit House Selbury Drive Oadby Le...

Page 2: ...as an aid for using the meter The CareSens N Voice Meter is also designed to minimize code related errors in monitoring by using the auto coding function You ll receive an accurate result in five seco...

Page 3: ...Results 22 Blood Glucose Testing Using the Lancing Device 23 Preparing the Lancing Device 24 Preparing the Meter and Test Strip 25 Marking Post meal Test Results 26 Applying Blood Sample 27 Discarding...

Page 4: ...designed to minimise code related errors in monitoring by using the auto coding function The CareSens N Voice Blood Glucose Meter should be used only with the CareSens N Test Strips An abnormally high...

Page 5: ...atteries Temperature 10 40 C 50 104 F Relative humidity 10 90 Hematocrit 20 60 CareSens NVoice BGM System includes the following items CareSens N Voice Blood Glucose Meter Owner s Booklet Quick Refere...

Page 6: ...And then swing it open Step 2 Remove the used batteries and insert two new batteries Close the battery cover firmly Note Removing the meter batteries will not affect your stored results However you m...

Page 7: ...rips only with clean and dry hands Do not bend cut or alter test strips in any way For detailed storage and usage information refer to the CareSens NTest Strip package insert Caution Keep the meter an...

Page 8: ...ng panel Blood insertion symbol indicates meter is ready for the application of a drop of blood or control solution 10 12 1 2 3 4 5 6 7 8 9 11 13 14 You should check and update the meter settings such...

Page 9: ...ext step Step 5 Setting the Time Format The meter can be set in an AM PM 12 hour or 24 hour clock format If the talking function is on the meter will say Set time 12 hour 24 hour Press or button to se...

Page 10: ...Step 10 Setting Your Hypoglycemic Level The hypoglycemic level can be set from 60 to 20 mg dL 3 3 to 1 1 mmol L To set your hypoglycemic level press or button until the level you want appears Press th...

Page 11: ...test strip vial Before using a new meter or a new vial of test strips you may conduct a control solution test following the procedure on pages 19 21 Notes Use only the CareSens Control Solution Check...

Page 12: ...ach test Remove the cap and squeeze the bottle to discard the first 1 or 2 drops Then wipe the tip with a clean tissue or cloth While the symbol blinks apply the control solution to the narrow edge of...

Page 13: ...rs Use a soft cloth or tissue to wipe the lancing device If necessary a small amount of alcohol on a soft cloth or tissue may be used Situations When the control solution bottle was not shaken well Wh...

Page 14: ...ustable tip until the setting number matches the arrow Step 4 Turn the adjustable tip until it is aligned with the load confirmation window and release button as shown in the diagram 1 2 3 4 5 6 7 3 4...

Page 15: ...ss and hold the button for 3 seconds after inserting the test strip The post meal flag and the symbol will appear on the screen If the talking function is on the meter will say Post meal test Please a...

Page 16: ...the symbol appearing on the screen If the meter turns off remove the strip reinsert and start from step 2 Step 10 After the symbol appears on the screen apply the blood sample to the narrow end of the...

Page 17: ...g forearm palm thigh calf Select a clean soft and fleshy sample site area free of visible veins and hair and away from bones Gently massage the sample site to help blood circulation to minimise result...

Page 18: ...mptoms Note If the sample drop of blood runs or spreads due to contact with hair or with lines on your palm do not use that sample Try puncturing again in a smoother area Things to KnowWhen Using AST...

Page 19: ...ith computer For more information contact the Spirit Healthcare 24 7 Freephone Support Line at 0800 881 5423 or go to www spirithealthcare co uk HI and Lo Messages HI Message The CareSens N Voice Mete...

Page 20: ...symbol for that test period Step 4 Viewing Post meal Averages On pressing the again 1 7 14 30 and 90 day average values and the number of tests performed post meals for the last test period will appea...

Page 21: ...seconds to set the post meal alarm PP2 the symbol and On will be displayed If the talking function is on the meter will say Post meal alarm is on The screen will then automatically change to the memo...

Page 22: ...er indicating the minute will start blinking Press to set the minute Step 2 On pressing alarm 1 is set and On is displayed on the screen Press again to cancel alarm 1 and OFF will blink on the screen...

Page 23: ...sources of strong electromagnetic radiation Keep the meter in a cool and well ventilated place Store all the meter components in the carrying case to prevent loss and keep the meter clean Understandin...

Page 24: ...Do not use the meter Contact the Spirit Healthcare customer service Message What is said The room temperature is too low The room temperature is too high The temperature during testing was below the o...

Page 25: ...confirmation window is filled completely Repeat the test after inserting a new test strip Repeat the test after inserting a new test strip Check the expiration date of the test strip Perform control s...

Page 26: ...ed by this warranty As a matter of warranty policy i SENS will not reimburse the consumer s purchase price Obtaining Warranty Service To obtain warranty service you must return the defective meter or...

Page 27: ...50 www i sens com MEMO...

Reviews: