![Spirax Sarco BSA3HP Installation And Maintenance Instructions Manual Download Page 7](http://html1.mh-extra.com/html/spirax-sarco/bsa3hp/bsa3hp_installation-and-maintenance-instructions-manual_1347908007.webp)
IM-P184-17
CMGT Issue 3
7
0 20 40 60 80 102.1
0 200 400 600 800 1000 1200 1400
425
400
300
200
100
0
-29
700
500
300
100
0
Te
mp
er
atu
re
°
C
Te
mp
era
tu
re
°
F
Pressure bar g
Pressure psi g
A
Steam
saturation
curve
D
E
Class 600
A-D-E
The product
must not
be used in this region or beyond the parameter of the PMA or TMA of the
relative end connection.
Body design condition
Class 600
PMA
Maximum allowable pressure
102.1 bar g @ 38 °C
1 481psi g @ 100 °F
TMA
Maximum allowable temperature
425 °C @ 57.5 bar g
797 °F @ 834 psi g
Minimum allowable temperature
-29 °C
-20 °F
PMO
Maximum operating pressure for saturated
steam service
79.8 bar g @ 295.8 °C
1 156 psi g @ 564.4 °F
TMO
Maximum operating temperature
425 °C @ 57.5 bar g
797 °F @ 834 psi g
Minimum operating temperature
-29 °C
-20 °F
Designed for a maximum cold hydraulic test pressure of:
154 bar g
2 233 psi g
Summary of Contents for BSA3HP