![Spirax Sarco ABV21i Installation And Maintenance Instructions Manual Download Page 17](http://html1.mh-extra.com/html/spirax-sarco/abv21i/abv21i_installation-and-maintenance-instructions-manual_1347905017.webp)
IM-P405-46
EMM Issue 5
17
6
5
5
8
11
12
Ball valve insert (
2
)
(not an available spare).
Please note:
You will need to order the
Insert
tool
listed in the table above to aid removal.
7
7
15
Table 1 Recommended tightening torques
Item no. Part
Size
N m
lbf ft
2
Insert
DN25 and DN32
108 - 135
80 - 100
DN40
135 - 160
100 - 120
DN50
215 - 245
160 - 180
DN65
245 - 270
180 - 200
15
Nut
DN25
17.5 - 20.3
13 - 15
DN32, DN40, DN50 and DN65
34 - 40
25 - 30
6.12 Switch box
To adjust switch box mircoswitch settings
a) Switch off power supply to switch box.
b) Remove switch box cover.
c) Remove indicator disc.
d) Turn the cam to the required position.
e) Replace indicator disc - ensure it is aligned correctly.
f) Replace cover and switch on air and power correctly.