4
LEAKS
If a smell of gas becomes apparent, the supply should be turned off at the
cylinder IMMEDIATELY.
Extinguish naked lights including cigarettes and pipes. Do not operate electrical
switches. Open all doors and windows to disperse any gas escape.
Butane/Propane gas is heavier than air; any gas escaping will therefore collect
at low level. The strong unpleasant smell of gas will enable the general area of
the leak to be detected. Check that the gas is not escaping from an unlit
appliance. Never check for leaks with a naked flame; leak investigation should
be carried out using a leak detector spray or soapy solution.
MAINTENANCE & SERVICING
This appliance needs little maintenance other than cleaning. All parts should be
cleaned using warm soapy water. Do not use abrasive cleaners, steel wool or
cleansing powders. When cleaning the burner ring it is essential to ensure that
the holes do not become blocked. The control knobs are a push fit and can be
removed for cleaning. They are interchangeable without affecting the sense of
operation.
On units fitted with battery spark ignition, when the time taken for spark
generation becomes extended, the battery should be renewed with a suitable
make of long life battery.
ALL SERVICING MUST BE CARRIED OUT BY AN APPROVED
COMPETENT PERSON. AFTER EACH SERVICE THE APPLIANCE MUST
BE CHECKED FOR GAS SOUNDNESS.
INSTALLATION INSTRUCTIONS
SPECIFICATION
This appliance is for use on LP Gas.
Spark ignition (where fitted) is 12V.
CAT I
3
+ (28-30/37)
CAT I
3
B/P (30)
BUTANE (G30) 28-30 mbar
BUTANE (G30) 30 mbar
PROPANE (G31) 37 mbar
PROPANE (G31) 30 mbar
External dimensions (WxD)
680 x 520
Heat input – Hotplate burners
1 x 1.0kW; 2 x 1.5kW; 1 x 1.8kW; 1 x 2.5kW
Injector size:- Hotplate burners
1.0kW = 0.50mm
1.5kW = 0.62mm
1.8kW = 0.67mm
2.5kW = 0.82mm