background image

MODEL HB10000  -  USER INSTRUCTIONS 
 
INTRODUCTION 
In your own interest of safety, it is law that all gas appliances be installed by 
competent persons. CORGI (Confederation for the Registration of Gas 
Installers) registered installers undertake to work to safe and satisfactory 
standards. Failure to install the appliance correctly could invalidate any warranty 
or liability claims and lead to prosecution. This appliance shall be installed in 
accordance with the local and national/European standards in force. Particular 
attention shall be given to the requirements regarding ventilation. Read the 
instructions before installing or using this appliance. 
 
PROVISION OF VENTILATION 
The use of a gas cooking appliance results in a production of heat and moisture 
in a room in which it is installed. Ensure that the kitchen is well ventilated: keep 
natural ventilation holes open or install a mechanical ventilation device, 
(mechanical extractor hood). 
Prolonged intensive use of the appliance may call for additional ventilation, for 
example opening a window, or more effective ventilation, for example 
increasing the level of mechanical ventilation where present. 
The room containing the cooker should have an air supply in accordance with 
local and national/European standards. 
IMPORTANT 
This appliance is suitable for use with Liquid Petroleum Gas (LPG) and should 
not be used on any other gas. The following gas pressures should be used: - 
 
 

  CAT I

3

+ (28-30/37)   

 

CAT I

3

 B/P (30) 

 

  BUTANE (G30) 28-30 mbar 

BUTANE (G30) 30 mbar 

 

  PROPANE (G31) 37 mbar  

PROPANE (G31) 30 mbar 

 
POSITION 
This appliance must be positioned free from draughts, which may affect the 
combustion, and in a manner that will prevent the accumulation of unburnt gas. 
When in use ensure that air vents are not inadvertently blocked or shut off. 
 
OPERATION 
Ensure the gas cylinder is turned on. 
In the event of a gas smell turn off at the cylinder and contact supplier. 
 
Burners - Each burner is controlled individually and is monitored by a flame 
supervision device. In the event of the burner flames being accidentally 
extinguished, turn off the burner control and do not attempt to re-ignite the 
burner for at least one minute. The respective knob positions are as shown in 
fig 1:- 
 
 

GB 

Summary of Contents for Country Leisure HB10000

Page 1: ...H LIQUIFIED PETROLIUM GAS USER AND INSTALLATION INSTRUCTIONS MODEL HB10000 4 Burner Hob CAUTION ALL OUTER SURFACES WILL GET HOT WHEN IN USE SPINFLO LIMITED 19 OAKHAM DRIVE PARKWOOD IND EST SHEFFIELD S3 9QX ENGLAND TEL 44 0 114 273 8157 FAX 44 0 114 275 3094 PCC1269 Issue 0 ...

Page 2: ... ventilation for example opening a window or more effective ventilation for example increasing the level of mechanical ventilation where present The room containing the cooker should have an air supply in accordance with local and national European standards IMPORTANT This appliance is suitable for use with Liquid Petroleum Gas LPG and should not be used on any other gas The following gas pressure...

Page 3: ...ally on initial lighting a small amount of yellow tipping will occur and then slightly increases as the burner heats up Each of the burners will accommodate pans from 10 to 22cm although care should be taken not to overload the appliance as reduced performance may result When using small pans the flame should not spread beyond the base of the pan as this will reduce the efficiency of the burner DO...

Page 4: ...t use abrasive cleaners steel wool or cleansing powders When cleaning the burner ring it is essential to ensure that the holes do not become blocked The control knobs are a push fit and can be removed for cleaning They are interchangeable without affecting the sense of operation On units fitted with battery spark ignition when the time taken for spark generation becomes extended the battery should...

Page 5: ...ts regarding ventilation Read the instructions before installing or using this appliance LOCATION OF APPLIANCE This appliance maybe installed in a kitchen kitchen diner but NOT in a room containing a bath or a shower LP gas appliances must not be fitted below ground level e g in a basement VENTILATION This appliance must be installed according to the relevant local and national European standards ...

Page 6: ...e or where applicable must not exceed the maximum allowable temperature to avoid damage as detailed within the suppliers material specification A horizontal difference of 200mm must exist between the edge of the burner and combustible material unless protected by a layer of non combustible material All combustible materials such as curtains and shelves must be kept well clear of the appliance This...

Page 7: ... in the worktop as shown below The unit should not be fitted in a position exposed to strong draughts since this always reduces the efficiency of the burners FIXING DETAILS SCREW FIXING DETAILS WITH HOB FIXED IN PLACE USING THE FIXING BUSHES PROVIDED ...