MODEL HB10000 - USER INSTRUCTIONS
INTRODUCTION
In your own interest of safety, it is law that all gas appliances be installed by
competent persons. CORGI (Confederation for the Registration of Gas
Installers) registered installers undertake to work to safe and satisfactory
standards. Failure to install the appliance correctly could invalidate any warranty
or liability claims and lead to prosecution. This appliance shall be installed in
accordance with the local and national/European standards in force. Particular
attention shall be given to the requirements regarding ventilation. Read the
instructions before installing or using this appliance.
PROVISION OF VENTILATION
The use of a gas cooking appliance results in a production of heat and moisture
in a room in which it is installed. Ensure that the kitchen is well ventilated: keep
natural ventilation holes open or install a mechanical ventilation device,
(mechanical extractor hood).
Prolonged intensive use of the appliance may call for additional ventilation, for
example opening a window, or more effective ventilation, for example
increasing the level of mechanical ventilation where present.
The room containing the cooker should have an air supply in accordance with
local and national/European standards.
IMPORTANT
This appliance is suitable for use with Liquid Petroleum Gas (LPG) and should
not be used on any other gas. The following gas pressures should be used: -
CAT I
3
+ (28-30/37)
CAT I
3
B/P (30)
BUTANE (G30) 28-30 mbar
BUTANE (G30) 30 mbar
PROPANE (G31) 37 mbar
PROPANE (G31) 30 mbar
POSITION
This appliance must be positioned free from draughts, which may affect the
combustion, and in a manner that will prevent the accumulation of unburnt gas.
When in use ensure that air vents are not inadvertently blocked or shut off.
OPERATION
Ensure the gas cylinder is turned on.
In the event of a gas smell turn off at the cylinder and contact supplier.
Burners - Each burner is controlled individually and is monitored by a flame
supervision device. In the event of the burner flames being accidentally
extinguished, turn off the burner control and do not attempt to re-ignite the
burner for at least one minute. The respective knob positions are as shown in
fig 1:-
GB