background image

other two LEDs are the indicators of the positive and
negative.  Note the rate in which the lights switch.
Your unit should be set at a slow rate.  Also note
when balancing, the indicator lights, as you offset
the positive and the negative (balance), the on and
off times changes on the lights.                      

3. Charge the 94052 to 1KV of either polarity ± and

push the decay button. The timer will automatically
time the decay rate.  The typical decay is 1,000 to
100 volts in under 60 seconds of  both polarities.

There are two adjustments that can be made on the
COUNTER  SPI: the BALANCE and the RATE.  The
BALANCE of positive and negative ion output can be
adjusted to increase polarity bias by inserting a small
screwdriver through the BALANCE port and slowly
turning the trimpot CLOCKWISE to increase positive
and decrease negative ON time pulses OR COUNTER
CLOCKWISE to increase negative and decrease
positive ON time pulses. The RATE or pulse frequency
can be adjusted down to one pulse per second or up to
5 pulses per second by inserting a small screwdriver
through the RATE port and slowly turning the trimpot
clockwise to increase and counterclockwise to
decrease the frequency.

REMEMBER: 

It is important to verify calibration after any adjustments
and before using your COUNTER SPI around sensitive
electronics.  Merely repeat above Balance Verification
steps after all adjustments.

Field repairs are not normally encouraged during the
warranty period.  Repair attempts by unqualified
personnel may invalidate the warranty.

IMPORTANT:

Your COUNTER SPI ionizer has been designed to
minimize effects of localized charges.  If your
processing involves generation of considerable static
charges you may need more aggressive equipment.
SPI has available a complete line of Ionizing Blowers,
Air Guns, Bars and Overhead Room systems to meet
all ionizing requirements.

TB-5508 

Page 2 of 2

Distributed by: All-Spec Industries

 • 

www.allspec.com

 • 

[email protected]

 • Phone (

80

0) 

537

-

0351

 • Fax (

80

0) 3

79

-9

90

3

© 2006 DESCO INDUSTRIES INC.

Employee Owned

Limited Warranty

SPI Westek expressly warrants that for a period of one (1) year
from the date of purchase, SPI Westek Counter SPI Ionizers will
be free of defects in material (parts) and workmanship (labor).
Within the warranty period, the product will be tested, repaired, or
replaced at our option, free of charge. Call our Customer Service
Department at 909-664-9986 for a Return Material Authorization
(RMA) and proper shipping instructions and address. Include a
copy of your original packing slip, invoice, or other proof of
purchase date. Any unit under warranty should be shipped prepaid
to the SPI Westek factory. Warranty repairs will take approximately
two weeks.

If your unit is out of warranty, call Customer Service at 909-664-
9986 for a Return Material Authorization (RMA) and proper
shipping instructions and address. SPI Westek will quote repair
charges necessary to bring your unit up to factory standards.

Warranty Exclusions

THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF
ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND
IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY
DISCLAIMED.  The express warranty will not apply to defects or
damage due to accidents, neglect, misuse, alterations, operator
error, or failure to properly maintain, clean or repair products.

Limit of Liability

In no event will SPI Westek or any seller be responsible or liable
for any injury, loss or damage, direct or consequential, arising out
of the use of or the inability to use the product.  Before using,
users shall determine the suitability of the product for their
intended use, and users assume all risk and liability whatsoever in
connection therewith.