Sperry instruments VD7504GFI Operating Instructions Download Page 2

 
Model: VD7504GFI

             OPERATING INSTRUCTIONS 

 

 

Sperry Instruments - N85 W12545 Westbrook Crossing Menomonee Falls, WI USA 53051 

Technical Support: 

1-800-624-4320, press 2

 

4. Activate the test button on the GFCI tester for a minimum of 6 seconds when testing the GFCI condition. Visible 
indication on the GFCI tester must cease when tripped.  
5. If the tester fails to trip the GFCI, it suggests: a.) a wiring problem with a totally operable GFCI, or b.) proper wiring 
with a faulty GFCI. Consult with an electrician to check the condition of the wiring and GFCI. 
 

Caution:

 GFCIs are sometimes installed in 2- wire systems (no ground wire available). This may or may not meet the 

local code. This tester will not trip GFCI outlets installed without a ground wire. On two wire systems use the test and 
reset buttons on the GFCI outlet to demonstrate proper operation. To detect which downstream outlets are protected 
by the GFCI place the tester in these outlets and use the test and reset buttons. Watch for the LEDs on the tester to turn 
off, this will indicate proper operation. 

 

 
Non-Contact Voltage Detection Operation:  

 

1. Before use test the battery

 by pressing the black button at the NVC detection end. The LED will flash and the speaker 

will chirp momentarily if the battery is good. If the indicators do not function or the chirp continually cycles, then replace 
the battery.  
2. To test for voltage press and hold the black button at the NVC detection end. Place the probe tip on or near the wire, 
device or circuit to be tested. If AC voltage greater than 50 VAC is present the LED will flash and the speaker will chirp 
continuously.  

 

Battery Instructions:  

Product comes complete with one LR44 BATTERY in package  
To Install or Replace: 
1) Orient the tester backside up, locate the battery compartment marked with the battery symbol secured with screw 
2) Once battery compartment is located, use a small Phillips head screwdriver to remove screw & release battery cover 
3) Remove the LR44 battery using caution to prevent damage or injury to the internal components 
4) Place battery into tester as shown on the battery cover (Positive terminal facing toward the NCV end of the product) 
5) Replace battery cover and screw 
6) Test on known live circuit to verify tester functionality 
 

 

NOTICE:  

1. Static Electricity – The tester is subject to electrical static interference. If the LED or tone activate momentarily it is 
detecting static electricity. When detecting voltage the LED and tone will cycle continuously.  
2. NCV detection antennae interference – The presence of objects near the probe tip can decrease the sensitivity of the 
tester. Keep your finger away from the LED lens and probe tip to ensure adequate detection range. 

 

 

CAUTION: 

REFER TO THIS MANUAL BEFORE USING THIS TESTER 
DO NOT ATTEMPT TO REPAIR THIS TESTER. IT CONTAINS NO SERVICEABLE PARTS 

 

 

Double Insulation: 

The tester is protected throughout by double insulation or reinforced insulation. 

 
 

Warning – 

This product does not sense DC voltage or potentially hazardous voltages below 50 volts. 

 

Warning – 

To assure the unit is operating, always test on a known live circuit before use. 

Warning – 

This tester will not detect voltages in wires that are electrically shielded by metal conduit or 

grounded electrical enclosures. 

      

 

Reviews: