Sperry instruments DSA2009TRMS Operating Instructions Manual Download Page 1

Figure 1

Functional Buttons

LCD Display 

Rotary Switch

Clam Jaw

Current Signal 

Output Terminal 

COM Terminal

Input Selector 

Trigger

1

OPERATING INSTRUCTIONS

13 Function True RMS Digital Clamp Meter 

DSA2009TRMS

IMPORTANT: RECEIVING INSTRUCTIONS

   

Visually inspect all components for shipping damage. If you find damage, 
notify the carrier at once.

Shipping damage is NOT covered by warranty. The carrier is responsible 
for all repair or replacement costs resulting from damage in shipment.

Dual insulation 

Diode

Grounding

Low battery

Warning prompt

AC or DC (Alternating current or direct current)

AC (Alternating current)

Danger! High voltage!

DC (Direct current)

Comply with EU standard

Continuity Test

I. DISPLAY SYMBOLS  (See Figure 2)

1

Low Battery

2

Manual Range

3

Auto Range

4

DC

5

Negative Polarity

6

AC 

7

True RMS

8

Low Pass Filter

9

DC Current # Clearing

10

Simulation Bar & Graduated Scale

11

Inrush

12

Voltage (Volt, millivolt)

13

Current (Amp)

14

Frequency (Hertz)

15

Resistance (

Ω

, k

Ω

, M

Ω

)

16

Capacitance (nF, uF, mF)

17

Diode

18

Continuity

19

Duty Ratio

20

Data Hold

21

Slave Display

22

Relative Value

23

Minimum Value

24

Maximum Value

25

Auto Shutdown

Read this owners manual thoroughly before use and save.

Input Terminal

Figure 2

1

4
5

6

8

9

11

3

2

18

15

13

14

16

12

17

10

19

20

24

23

25

22 21

7

Summary of Contents for DSA2009TRMS

Page 1: ...mpt AC or DC Alternating current or direct current AC Alternating current Danger High voltage DC Direct current Comply with EU standard Continuity Test I DISPLAY SYMBOLS See Figure 2 1 Low Battery 2 M...

Page 2: ...ons Understand and follow all the safety instructions contained in the manual It is essential that all safety instructions are adhered to Failure to follow the safety instructions may cause injury ins...

Page 3: ...nments can endure greater momentary energy than one designed for CAT II CAT I Secondary electrical circuits connected to an AC electrical outlet through a transformer or similar device CAT II Primary...

Page 4: ...libration time Ambient temperature 23 C 5 C Ambient humidity 80 RH Temperature coefficient 0 1 accuracy C 1 DC voltage V Input impedance 10M 2 AC voltage V Main display true RMS voltage Main display f...

Page 5: ...the display will show the DC voltage value being measured If the potential at the red test leads is higher than the potential at the black test leads the display will either show a positive voltage va...

Page 6: ...measurement can be achieved by separating the component from the circuit being tested 4 DIODE MEASUREMENT See Figure 6 1 Insert test leads Insert the black test lead into the COM input and the red tes...

Page 7: ...Test Measure Using the trigger open the clamp meters jaw and clamp around the conductor Make sure that the conductor is positioned in the center and that the flow of current matches the arrow located...

Page 8: ...he main display will show Dn Df Df is displayed on slave display screen Df relative value is the last measured value prior to pressing the REL key while Dn is the current measured value After pressing...

Page 9: ...shall not have been altered by the distributor The distributor shall be fully responsible for any warranties the distributor makes to its purchasers which are broader or more extensive than Sperry s l...

Reviews: