OPERATING INSTRUCTIONS

Digital Clamp Meter 

DSA660

Rotary Switch

NCV

Non-Contact Voltage Measurement
Continuity Test/Diode Test/
Resistance Measurement
DC Voltage Measurement
AC Voltage Measurement

600

AC Current Measurement

60

AC Current Measurement

OFF

Power Off

A

400A

A
A

A

400A

A
A

A

400A

A
A

A

400A

Function Selection

BUTTON

OPERATION PERFORMED

SELECT

Switch between Continuity, Diode, and Resistance at the 

 measurement settings

REL 

Display the difference between the measured value and the stored value  

on the LCD screen

Hz/DUTY

Measure Frequency / Measure Duty Cycle

MAX/MIN

Retain the highest or lowest measurement value being recorded

HOLD/ 

Retain the measured value on the LCD screen / Turn on display backlight

Read this owners manual thoroughly before use and save.

IMPORTANT: RECEIVING INSTRUCTIONS

   

Visually inspect all components for shipping damage. If you find damage, notify the carrier at once. 
Shipping damage is NOT covered by warranty. The carrier is responsible for all repair or replacement costs resulting from damage in shipment.

LCD

COM

Input

MAX/MIN

HOLD / Backlight

Rotary Switch

Function

Relative

Clamp

Trigger

Frequency / Duty Cycle

Figure 1

Summary of Contents for DSA-540A

Page 1: ...red value and the stored value on the LCD screen Hz DUTY Measure Frequency Measure Duty Cycle MAX MIN Retain the highest or lowest measurement value being recorded HOLD Retain the measured value on th...

Page 2: ...Frequency measurement up to 9 999MHz Relative measurement Used for comparative measurement Duty cycle measurement 0 1 99 9 Maximum and minimum value hold 2 SAFETY WARNINGS This instruction manual cont...

Page 3: ...for current measurement Do not expose the instrument to the direct sun high temperature and humidity or dewfall Be sure to power off the instrument after use When the instrument will not be in use fo...

Page 4: ...40Hz 400Hz AC VOLTAGE RANGE RESOLUTION ACCURACY 100HZ 0 01HZ 0 5 4 1KHZ 0 1HZ FREQUENCY RANGE RESOLUTION ACCURACY 600mV 0 1mV 1 0 3 6V 0 001V 60V 0 01V 600V 0 1V Input Impedance 10M DC VOLTAGE RANGE R...

Page 5: ...Check test lead condition continuity and rating Do not use damaged test leads Examine the test leads for worn or cracked insulation Check test lead continuity Do not use test leads in applications th...

Page 6: ...be achieved by separating the component from the circuit being tested 5 2 AC DC Voltage AC VOLTAGE A A A 400A 1 Insert test leads Insert the black test lead into the COM input and the red test lead in...

Page 7: ...e value is being retained 4 Press the HOLD button again press the SELECT button or move the rotary dial to resume normal operation 6 4 Backlit LCD Display 1 Press and hold the HOLD button for at least...

Page 8: ...r is sensitive to electrostatic fields Occasionally a static charge may interfere with the meter detection and the meter may omit a tone momentarily NCV 600A 60A V Hz 7 BATTERY REPLACEMENT 8 MAINTENAN...

Page 9: ...s original purchasers in connection with the sales of Sperry products provided that such products shall not have been altered by the distributor The distributor shall be fully responsible for any warr...

Reviews: