background image

2

DANGER is reserved for conditions and actions that are likely to cause serious or fatal injury.

WARNING is reserved for conditions and actions that can cause serious or fatal injury.

CAUTION is reserved for conditions and actions that can cause injury or instrument damage.

DANGER

• Never make measurement on a circuit in which voltage over 1000V exists.

• Do not exceed the CAT rating of the measuring device

•  Do not attempt to make measurement in the presence of flammable gases.  

The use of the instrument may cause sparking, which can lead to an explosion.

• Never use the instrument if its surface or your hand is wet.

• Do not exceed the maximum allowable input of any measuring range.

• Never open the battery cover during a measurement.

•  The instrument is to be used only in its intended applications or conditions.  

Use in other than as intended may cause instrument damage or serious personal injury.

WARNING

•  Never attempt to make any measurement if any abnormal conditions are noted, such as broken case,  

cracked test leads and exposed metal part.

• Do not turn the function selector switch with plugged in test leads connected to the circuit under test.

•  Do not install substitute parts or make any modification to the instrument.  

Return the instrument to your distributor for repair or recalibration.

• Do not try to replace the batteries if the surface of the instrument is wet.

• Always switch off the instrument before opening the battery compartment cover for battery replacement.

• Set the Function Switch to an appropriate position before starting measurement.

• Firmly insert the test leads.

• Disconnect the test leads from the instrument for current measurement.

• Do not expose the instrument to the direct sun, high temperature and humidity or dewfall.

•  Be sure to power off the instrument after use. When the instrument will not be in use for a long period,  

place it in storage after removing the batteries.

•  Use only a soft cloth dampened with water or neutral detergent for cleaning the meter.  

Do not use abrasives, solvents or harsh chemicals. Allow to dry thoroughly before use.

CAUTION

Measurement categories (Over-voltage categories) 

To ensure safe operation of measuring instruments, IEC61010 establishes safety standards for various electrical 

environments, specified as CAT I through CAT IV, and called measurement categories. Higher-numbered categories 

correspond to electrical environments with greater momentary energy, so a measuring instrument designed for CAT III 

environments can endure greater momentary energy than one designed for CAT II.
• CAT I: Secondary electrical circuits connected to an AC electrical outlet through a transformer or similar device. 

• CAT II: Primary electrical circuits of equipment connected to an AC electrical outlet by a power cord. 

•  CAT III: Primary electrical circuits of the equipment connected directly to the distribution panel, and feeders  

from the distribution panel to outlets. 

•  CAT IV: The circuit from the service drop to the service entrance, and to the power meter and primary over  

current protection device (distribution panel).

Incoming wire

Interior wiring

CAT. III

Transformer CAT. II

CAT. I

CAT. IV

Socket

Symbols

Caution, risk of danger, refer to the operating manual before use

Caution, risk of electric shock

AC (Alternating Current)

DC (Direct current)

AC/DC Selectable (Alternating Current/Direct Current)

Earth (ground) Terminal

The equipment is protected throughout by  
double insulation or reinforced insulation

Application around and removal from hazardous  
live conductors is permitted.

Conforms to Standards of European Union

Designates the product as recyclable  

electronic waste per WEEE Directive

Reviews: