Air flow measurement

1.  With the Power on, select Air flow mode 

 

(refer to page 9)

2.  Set the measurement area dimension: 

 

Press 

Hold

 once, the display will show 

HOLD

  

then press 

REC

 continuously until the lower left  

of the Display shows m-2 or F-2

m-2 = meter square

F-2 = ft square

The unit of measure is determined by the  

selected scale CMM or CFM

3.  Use 

Hold

 and 

 to adjust the air flow dimension 

value. When the desired dimension value is set, 

press 

REC

 to save as the default.

 button = ▲button

Hold

 button = ▼ button

REC

 button = Enter button

Hold Function

Pressing 

Hold

 will freeze the current reading on the 

display. The HOLD symbol will be displayed at the top 

of the display window.

To release the Hold function, press 

Hold 

again, the 

HOLD indicator will disappear and the current reading 

will be displayed.

Summary of Contents for 850026

Page 1: ...Mini Environmental Quality Meter 850026 Eastern Energy Co Ltd 40 4 Vitoondumri Rd Banbueng Banbueng Chonburi Thailand Tel 66 3844 6117 sale ete co th www eastern energy com...

Page 2: ...USA The contents of this manual may not be reproduced or transmitted in any form or by any means electronic mechanical or other means that do not yet exist or may be developed including photocopying...

Page 3: ...6 5 OPERATING INSTRUCTIONS 7 Power on off 7 LCD backlight on off 7 Mode selection 7 Unit selection 9 Special attention for the Humidity measurement 9 Air flow measurement 10 Hold Function 10 REC Recor...

Page 4: ...environmental test functions into a single compact unit Features include touch tone buttons min max and hold functions Comes ready to use with wrist strap instructions battery and soft carrying case M...

Page 5: ...iction ball bearing mounted impeller design provides high accuracy at high and low air velocity High precision humidity sensor with fast response time Built in microprocessor circuit assures excellent...

Page 6: ...Anemometer Vane 3 7 Humdity Temp sensor 3 8 Battery Compartment Cover 3 9 Buttons operation label 3 10 Anemometer Temp sensor 3 6 4 1 7 2 3 9 8 5 1 Hold button 2 Button Power button 3 REC button 4 LC...

Page 7: ...the meter on press once The LCD backlight will light for 5 seconds then shut off automatically Mode selection This meter offers 7 selectable modes a Anemometer Air velocity Temp b Air flow CMM CFM c...

Page 8: ...the default Anemometer Air Velocity Temp Measurement Unit Selection REC button Enter button 1 With the power on press REC for 3 seconds the display will show Unit Release REC then press to scroll thro...

Page 9: ...e Measurement Scales Air Velocity m s Km h mph knot FPM Temp Air velocity C F Air flow CMM CFM Wind chill C F Temp Humidity C F Dew point C F Wet bulb Temp C F Heat index C F Note For the most accurat...

Page 10: ...s determined by the selected scale CMM or CFM 3 Use Hold and to adjust the air flow dimension value When the desired dimension value is set press REC to save as the default button button Hold button b...

Page 11: ...m value c Clear the recorded MAX or MIN value from the display by pressing Hold once The MAX MIN symbols and their readings will disappear from the display The meter will return to the REC function an...

Page 12: ...and replace the cover GENERAL SPECIFICATIONS Display 8 mm LCD display Measurement 1 Anemometer Air velocity Temp 2 Humidity Temp 3 CMM CFM 4 Dew point 5 Wet bulb 6 Wind chill 7 Heat index Operating Hu...

Page 13: ...80 3927 1 20 m s 3 F S 20 m s 4 F S m s 0 4 20 0 0 1 km h 1 4 72 0 0 1 mph 0 9 44 7 0 1 knots 0 8 38 8 0 1 Temp C F 0 50 C 0 1 C 1 2 C 32 122 F 0 1 F 2 5 F ft min feet per minute m s meters per second...

Page 14: ...Flow Unit Range Res CMM 0 024 36000 0 001 0 01 0 1 1 CFM 0 847 1271300 0 001 0 01 0 1 1 10 x10 100 x100 ELECTRICAL SPECIFICATIONS Dew point Temp Unit Range Res Remark C 25 3 49 0 0 1 Calculate from th...

Page 15: ...de values C F Notes 27 32 80 90 Caution Fatigue is possible with prolonged exposure and activity Continuing activity could result in heat cramps 32 41 90 105 Extreme caution Heat cramps and heat exhau...

Page 16: ...does not cover probes batteries battery leakage or damage resulting from accident tampering misuse or abuse of the product Opening the meter to expose its electronics will void the warranty To obtain...

Reviews: