SL2KW SERIES MANUAL
14
118088-001 REV C
High Voltage Power
Supply Internal inhibit circuitry.
2.2k
All cables should be shielded with the shields
being returned to the chassis ground of the
The transistor should be located as close as possible
High Voltage Power Supply.
to the power supply
+15V
4
3
2
1
PS Common
J5
Transistor
Voltage
ON
High
Inhibits
Figure 3.5 – External Inhibit Interface Circuit
External Safety
Interlock Control
J5
All cables should be shielded with the shields being returned
to the chassis ground of the High Voltage Power Supply.
Remove jumper
for remote
external interlock
S1 Open= Interlock Open
S1 Closed= Interlock Closed
3
S1
5
4
1
2
Relay contacts are recommended for S1. The relay
should be located as close as possible to the power supply.
Signals are at 15Vdc, 25mA max and are only to be used
for contact closure.
Figure 3.6 – External Interlock Interface