6

This tool vibrates during use. Repeated or long-term exposure to vibration may cause

temporary or permanent physical injury, particularly to the hands, arms, and shoulders. To

reduce the risk of vibration-related injury:

1.

 Anyone using vibrating tools regularly or for an extended period of time should first be

examined by a doctor and then have regular medical check-ups to ensure medical

problems are not being caused or worsened from use. Pregnant women or people who

have impaired blood circulation to the hand, past hand injuries, nervous system disorders,

diabetes, or Raynaud s Disease should not use this tool. If you feel any symptoms related

to vibration (such as tingling, numbness, and white or blue fingers), seek medical advice

as soon as possible.

2. 

Do not smoke during use. Nicotine reduces the blood supply to the hands and fingers,

increasing the risk of vibration-related injury.

3. 

Wear suitable gloves to reduce the vibration effects on the user.

4. 

Use tools with the lowers vibration when there is a choice.

5. 

Include vibration-free periods each day of work.

6. 

Grip the tool as lightly as possible (while still maintaining a secure hold). Let the tool do

the work.

7. 

To reduce vibration, maintain tool as explained in this manual. If abnormal vibration

occurs, stop immediately.

Important Operating Instructions

VIBRATION PRECAUTIONS

INITIAL SETUP & ASSEMBLY

Air Supply
WARNING: 

To prevent serious injury from explosion, use only clean, dry, regulated,

compressed air to power this tool. Do not use oxygen, carbon dioxide, combustible gases,

or any other bottled gas as a power source for this tool.

1. 

Incorporate a filter, regulator with pressure gauge, oiler, in-line shutoff valve, and quick

coupler for best service. Refer to the diagram at the end of this manual for more

information. 

An in-line shut-off ball valve is an important safety device because it

Summary of Contents for 44676

Page 1: ...product Observe all safety information to protect yourself and others Failure to observe the instructions may result in property damage and or personal injury Please keep instructions for future refer...

Page 2: ...mplete operating manual with due care Keep this manual in a safe place so that the information is available at all times If you give the equipment to any other person give them these operating instruc...

Page 3: ...ons as a result of being caught in moving parts Avoid unintentional starting Be sure the switch is off before connecting to the air supply Do not carry the tool with your finger on the switch or conne...

Page 4: ...e controlled with the switch is dangerous and must be repaired Disconnect the tool from the air source before making any adjustments changing accessories or storing the tool Such preventive safety mea...

Page 5: ...njury Important Operating Instructions GENERAL SAFETY INSTRUCTIONS The warnings and precautions discussed in this manual cannot cover all possible conditions and situations that may occur It must be u...

Page 6: ...icotine reduces the blood supply to the hands and fingers increasing the risk of vibration related injury 3 Wear suitable gloves to reduce the vibration effects on the user 4 Use tools with the lowers...

Page 7: ...to allow free movement while working 3 Release the tool s trigger 4 Close the in line shut off valve between the compressor and the tool 5 Turn on the air compressor according to the manufacturer s d...

Page 8: ...f Pneumatic Tool Oil to the airline connection before use Add a few drops more after each hour of continual use IMPORTANT Before each use test the Shear on scrap material of the same weight and hardne...

Page 9: ...the tool only with specified lubricants Lubricate the air inlet using only pneumatic tool oil Other lubricants may damage the mechanism and may be highly flammable causing an explosion Note These proc...

Page 10: ...r damaged Have the internal mechanism cleaned inspected and lubricated by a qualified technician If the vanes need replacement replace them all as a set A Remove the two Socket Head Screws 30 and Nuts...

Page 11: ...amaging tool or work piece Adjusts air pressure on tool Air tool lubrication Provides quick connection and release Increases coupler life Prevents water vapor from damaging work piece Fine tuning airf...

Page 12: ...icate using air tool oil and grease according to directions 4 Clean air inlet screen of buildup 5 Make sure housing is properly assembled and tight 6 Have qualified technician clean and lubricate mech...

Page 13: ...to defects due directly or indirectly to misuse abuse negligence or accidents repairs or alterations or a lack of maintenance FOT shall in no event be liable for death injuries to persons or property...

Page 14: ...348 5004 or e mail customerservice focus ontools com 14 PARTS LIST Pistol Grip Air Shears Model 44676 88007621 02 2014 8 6 25 29 27 24 23 22 21 20 19 33 30 35 34 32 31 38 28 36 37 17 16 16 15 14 13 12...

Page 15: ...Bearing 1 11 Washer 1 12 Internal Gear 1 13 Planet Gear 3 14 Pin 3 15 Link Spindle 1 16 Ball Bearing 2 17 Spring 1 18 Clamp Nut 1 19 O Ring 1 20 Valve Spindle 1 Part Description Qty 21 O Ring 2 22 Bu...

Reviews: