Speedotron 4803CX Instruction Manual Download Page 5

4

8

0

3

C

X

L

V

p

o

w

e

r

s

u

p

p

ly

4

8

0

3

C

X

L

V

p

o

w

e

r

s

u

p

p

ly

8

9

4803CX LV Power Ratios

Ratios apply to independent use of standard outlets. The four standard outlets represent:
1 - 800Ws single outlet, & 1 - 1600Ws single outlet which form the left channel; & 1 high power
double outlet which forms the 2400Ws center channel.

NOTE: Power is shared between the top high power outlet and the two left standard outlets (“X’s”

in the above diagram); power is also shared between the bottom high power outlet and the middle

two outlets. (“O’s” in the above diagram)

HIGH

POWER

CHANNEL

AND

OUTLETS

STANDARD

POWER

CHANNELS

AND

OUTLETS

HIGH

POWER

CHANNEL

AND

OUTLETS

STANDARD

POWER

CHANNELS

AND

OUTLETS

x

x

x

O

O

O

4803CX LV Operating Instructions

The following sequence of operation should be utilized for maximum

life and dependability of the 4803CX LV power supply.

Make sure that the

Model

and

Power

switches are in the off position and

the

Reset

button (circuit breaker) is fully depressed into its socket.

Connect light unit cable(s) to the

Light Unit Outlet(s)

on the power

supply, selecting the appropriate outlet(s) for the desired power level. Any
Black Line Universal Light Unit may be attached to the left and center

Light

Unit Outlets.

Only Model 206VF light units may be attached to the right

Light Unit Outlets.

(See Universal Light Units section of this manual for

information on assembling light units.)

Set

Isolate/Combine

switches and

Variable Power Control

as desired.

See the side of the power supply for various ratio combinations. With the

Variable Power Control

in the full position, power is determined by the

choice of outlets and position of ratio switches. The

Variable Power Control

simultaneously changes power of all three channels. Rotating the

Variable

Power Control

immediately adjusts the power level of the 4803CX LV. The

power supply does not need to be discharged between settings.

Turn

Power

switch to on position. The red

Charge

indicator will

illuminate. After a few seconds, the green

Ready

indicator will illuminate and

an audible beep will sound. (The beep will not be produced when a very
small power change is made. Changing the power level by a 1/3 f-stop or so
is done very rapidly with the 4803CX LV; the

Ready

light will usually remain

on and the beep will not sound.) The power supply is now charged to the
selected level, and ready to fire.

Do not

immediately fire the unit on the first use or when the unit has

been idle for periods over 3 weeks. Allow several minutes for the power
supply’s capacitors to form. When the power supply has been used recently
you may fire the unit immediately.

Push to Flash

button may be depressed

to verify proper system operation.

When Power is on, be sure

Ready

indicator is illuminated before

switching

Power

or

Fast/Slow.

Do not

move these switches while the unit

is recycling.

When changing light ratios by moving light cables, we recommend that

you turn the power supply off. Though arc-protection is included with all
Speedotron systems, the safest method for changing ratios is to turn the
power off before moving the light unit cables.

When disassembling the system, turn

Power

switch to the off position.

The 4803CX LV power supply will automatically discharge its storage

capacitors.

Do not

push the

Push to Flash

switch before turning power

supply off. This may damage power supply. Power supplies may flash their
light units when turned off. This is normal.

Unplug power cord from outlet, then disconnect light units from power

supply.

Summary of Contents for 4803CX

Page 1: ...on the care and proper use of all including the latest Speedotron products This manual is not a photographic handbook only information pertinent to basic operation is given If you have questions about...

Page 2: ...el or by the user will void the warranty Although we do have several service stations we encourage you to send all repairs under warranty or otherwise to our factory to ensure the best possible servic...

Page 3: ...mation General Instructions and Information Although Speedotron Black Line power supplies vary in power and features they all operate under the same principles The following instructions apply to the...

Page 4: ...on page 20 5 Variable Power Control simultaneously controls power of all three channels with ten positions down to 3 stops 1 8 power Power ratios among the light units are unaffected since there is a...

Page 5: ...es The Variable Power Control simultaneously changes power of all three channels Rotating the Variable Power Control immediately adjusts the power level of the 4803CX LV The power supply does not need...

Page 6: ...consistent color temperature and light output Dirt and dust deposits on the tube and reflector act like a filter to alter color To extend the life of the model lamp it should be turned off after set u...

Page 7: ...s qty regular or color corrected _______________________________________________________________________________ 102 2400 1 MW8QV or 1 MW8QVC economical general purpose 103 2400 1 MW9Q or 1 MW9QC ligh...

Page 8: ...aulty materials or workmanship or breakdowns from normal use except as hereinafter provided Damage to equipment or its parts arising out of misuse abuse negligence shipping or causes beyond Speedotron...

Page 9: ...________________________________________________________________ Speedotron acceptance Speedotron agrees to provide repair service for the equipment listed in this agreement according to the terms and...

Reviews: