Model SC-VSC-7000 Operating and Maintenance Manual
Troubleshooting
PROBLEM
PROBABLE CAUSE
SOLUTION
Steam is leaking from the
hose or accessory.
• Broken o-ring on connector.
• Steam hose is punctured.
• Check to connector for any
broken seal and replace
if needed.
• Turn off the unit immediately
and contact SpeedClean to
replace the hose.
There is no steam
output, but there is
boiler pressure.
• Steam regulator valve on
the machine is closed.
• Trigger on the steam output
hose assembly is broken.
• Turn the regulator valve
counterclockwise to open the
valve for steam.
• Call SpeedClean to have the
trigger switch replaced.
Machine heating time is
too long.
• Too much limescale buildup
in the boiler.
• Follow the instructions on page
5 under MAINTENANCE to
remove the limescale from
the boiler.
Problem Not Listed Call Speedclean Customer Service: 1-888-700-3540
SC-VSC-7000
Power Requirements
115V 60 Hz 13.5A/230V 50 Hz 7A
Power Supply Cord
13’ (3.3M)
Steam Hose Length
10’ (3M)
Water Capacity
0.66 Gallons (2.5L)
Max Steam Temp (at Nozzle)
235˚F (113˚C)
Max Steam Pressure
65 PSI (4.5 BAR)
Weight
15.6 Lbs (Dry)
Specifications
Maintenance & Storage
Maintenance
The water filter must be cleaned periodically. To do this, you have to remove it from where the
water is poured into the water tank. Routine checks carried out by SpeedClean will increase the
life and reliability of the unit.
To prevent the buildup of Limescale, the boiler should be emptied and cleaned every 6-12
months. To do this, remove the slotted cap on the bottom of the machine, and then remove the
hex cap using the supplied hex socket. To remove the limescale, use SpeedyBright
®
and agitate
the limescale until it is removed and the SpeedyBright
®
is no longer reacting.
Storage
To prevent damage to the boiler, store this unit in a vertical position, and do not store in
freezing temperatures.