General Maintenance & Storage
Troubleshooting
PROBLEM
PROBABLE CAUSE
SOLUTION
Inconsistent and/or
erratic pressure
• Nozzle worn
• Nozzle clogged
• Water/chemical is low
• Air sucked into system
• Air in pump
(not properly primed)
• Vacuum lock
(cap vent clogged)
• Water temp too high
• Replace nozzle
• Clean nozzle orifice
• Add water and/or chemical
• Fill Tank(s)
• Remove nozzle, prime pump
• Clean cap air vent
• Add cold water to reduce temp
Motor continues to run
even though trigger is
released
• High pressure system or
pump hydraulic circuit
not watertight
• Air in system
• Tank(s) empty
• Garden hose off
• Check for leaks at spray gun
and pump
• Re-prime the unit
• Fill tank(s)
• Turn valve on
Motor stops abruptly
• Power switch off
• Thermal breaker tripped
• Plug not connected properly
• GFCI was tripped
• Turn switch on
• Turn off, let unit cool
• Place plug completely into receptacle
• Reset GFCI
Motor buzzes but fails
to start or does not start
at all
• Problems with pump
auto shut-off
• Unit in disuse for
extended time
• Pressure needs to be relieved
• Contact factory
• Contact factory
• Squeeze trigger and
relieve pressure
water tank not priming
air block in the line
Prime machine through the garden
hose side. Prime the tank with the
garden hose still attached then take
off the garden hose.
Plumbing and Wiring Diagrams
CJ-200E
Pump
HWP-38FNPT-25B
CJ2-Y-BRB-025
CJ2-GHC
1006
1006
Garden
CJ2-SPHN-38MNPT
CJ2-08
Tank
CJ2-07
Tank
Chemical
9608
Water
Hose In
933
CJ2-05-115
CJ2-08
CJ2-25B25NPT
CJ2-3WAY-VALVE
Out to Spray Gun
In
Out
CJ2-07-1
8933
CJ2-07-1
Plumbing Diagram
Breaker
Power Switch
Circuit
120VAC
L2
L2 = White
L1
L3 = Ground
L3
L1 = Black
Pump
~
Wiring Diagram
P/N : MNL- CJ20 0E 0119
PO Box 110301, Stamford, CT 06911-0301
(888) 700-3540 www.speedclean.com
CJ-200E
SpeedClean is a registered trademark of Crossford International.
SpeedClean reserves the right to improve products;
contact the factory for the latest configuration and uses.