background image

General Safety Information

Because SpeedClamps and other components
(compressor, filters, regulators, lubricators,
spray gun, hoses, etc.) make up a high air
pressure pumping system, the following
safety precautions should be observed at all
times.
1. Read the instruction manuals for each

component carefully before attempting to
assemble, disassemble, or operate your
particular system.

2. Do not exceed the pressure rating of any

component in the system.

3. Protect material lines and air lines from

damage or puncture.

4. Never point a spray gun at oneself or any

other person. Accidental discharge may
result in serious injury.

5. Check hoses for weak or worn condition

before each use, making certain that all
connections are secure.

6. Release all pressures within the system

before attempting to service any
component.

Materials

Body: Zinc
Elastomers: Nitrile

O-ring service kit (contains 2)

Compact SpeedClamp: 4384-570
Standard SpeedClamp: 4384-770

Tools Required

Compact SpeedClamp: 3mm hex or T15 Torx
wrench for screw (Ref Nos. 3, 5).
Standard SpeedClamp: 5/32" (4mm) hex or
T25 Torx wrench for screw (Ref Nos. 8, 9, 10).

Compact Series SpeedClamp/Wall
Bracket (See Figure 1)

The Compact Series SpeedClamp does not
use o-ring grooves to retain the face-sealing
o-rings. O-rings are retained by grooves in
the Compact Series FRL unit.
If optional wall bracket (Ref. No. 1) is not
assembled to SpeedClamp (Ref. No. 2):
1. Remove screw (Ref. No. 3) from

SpeedClamp.

2. Attach wall bracket to SpeedClamp using

screw (Ref. No. 3). Tighten screw (Ref. No.
3) as shown in the Torque Table.

Standard Series SpeedClamp/Wall
Bracket (See Figure 2)

The Standard Series SpeedClamp has o-ring
grooves that retain the face-sealing o-rings.
If optional wall bracket (Ref. No. 6) is not
assembled to SpeedClamp (Ref. No. 7):
1. Remove and discard screw (Ref. No. 10).
2. Attach wall bracket to SpeedClamp using

screw (Ref. No. 11). Tighten screw (Ref.
No. 11) as shown in the Torque Table.

Attach FRL Units to SpeedClamp

1. Loosen captive screw (Ref. No. 12), then

open clamp.

2. Compact SpeedClamp - Make sure o-rings

are securely in place in the o-ring grooves
in the FRL units.
Standard SpeedClamp - Make sure o-rings
are securely in place in the o-ring grooves
in the SpeedClamp.

3. Engage the port flanges on the FRL unit

with the V-grooves in the SpeedClamp,
then slide the units into SpeedClamp.

NOTE:

SpeedClamp can be installed in any of

four orientations over the port flanges on
the FRL units.
4. Close the clamp and tighten the captive

screw (Ref. Nos. 5, 9) as shown in the
Torque Table. Do not tighten or adjust
clamps when SpeedClamp is under pressure.

Install in Air Line (See Figure 3)

1. Connect system pipe to proper ports using

pipe thread sealant on male threads only.
Do not allow sealant to enter interior of
FRL unit.

2. Hold FRL unit with a pipe wrench on the

body, the port flange (Ref. No. 13), or the
pipe adapter (Ref. No. 14), then tighten
pipe (Ref. No. 15) into ports.

Failure to hold FRL unit in
place with a wrench

when turning pipe (Ref. No. 15) into ports
may result in damage to the SpeedClamp
and the SpeedClamp wall bracket.

Remove FRL Units from SpeedClamp

1. Shut off inlet pressure. Reduce pressure in

inlet and outlet lines to zero.

2. Loosen captive screw (Ref. No. 12), open

clamp, and remove unit.

Torque Table
Ref. No.

Inch Pounds (N-m)

3, 5 (Screw)

15 to 25 (1.7 to 2.8)

9 (Screw)

30 (3.4)

11 (Screw)

40 (4.5)

Do not loosen or tighten
captive screw (Ref. No.

12) when the SpeedClamp is pressurized. If
screw is loosened when SpeedClamp is
pressurized, an audible air leak warns of air
pressure. If screw is over-torqued when the
Speedclamp is pressurized, the threads can
be damaged and system pressure may
rapidly open the clamp (Ref. Nos. 4, 8).

Speedaire

®

SpeedClamp

Refer to Form 5S6040 for General Safety Information and Warranty

Operating Instructions & Parts Manual

4ZK24, 4ZK25, 4ZK35, 4ZK36

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for
future reference.

Form 5S6053

®

E

N
G

L

I

S

H

E
S
P

A
Ñ
O

L

F

R

A
N

Ç

A

I

S

Printed in U.S.A.
06530
0708/216/VCPVP

Description

SpeedClamps

provide modular installation capability for

Compact Series

and

Standard Series

Speedaire filters, regulators, lubricators, and lock out valves

(FRL’s)

. Flanges on the FRL ports

slide into V grooves in the SpeedClamp. Two face-sealing o-rings in the SpeedClamp provide
a positive seal when the clamp is closed and a captive screw is tightened.

Specifications

Maximum
Inlet

Maximum

Speedaire

Model

Pressure

Temperature

Description

Series

4ZK24

250 psi

150°F

SpeedClamp

Compact

4ZK25

250

150

SpeedClamp with wall mounting bracket Compact

4ZK35

250

175

SpeedClamp

Standard

4ZK36

250

175

SpeedClamp with wall mounting bracket Standard

13

14

15

15

12

FRL Units

1

3

2

4

5

6

10
Discard existing
1/2" (13 mm) long screw

11
5/8" (16 mm)
long screw
in kit

7

8

9

Figure 1. Compact Series SpeedClamp/Wall

Bracket

Figure 2. Standard Series SpeedClamp/Wall

Bracket

Figure 3. FRL Installation

5S6053:5S4355

7/24/08  10:56 AM  Page 1

Summary of Contents for SpeedClamp 4ZK24

Page 1: ...own in the Torque Table Do not tighten or adjust clamps when SpeedClamp is under pressure Install in Air Line See Figure 3 1 Connect system pipe to proper ports using pipe thread sealant on male threads only Do not allow sealant to enter interior of FRL unit 2 Hold FRL unit with a pipe wrench on the body the port flange Ref No 13 or the pipe adapter Ref No 14 then tighten pipe Ref No 15 into ports...

Page 2: ... tornillo prisionero Refs No 5 y 9 como se indica en el cuadro de pares de apriete No apriete ni ajuste las abrazaderas cuando estén bajo presión Instalación en una línea de aire vea la Figura 3 1 Conecte la tubería del sistema a través de los orificios de conexión correspondientes y aplíquele compuesto obturador para roscas de tubería sólo a las roscas exteriores No permita que el compuesto pase ...

Page 3: ...leau des couples de serrage Ne pas serrer ou ajuster les pinces lorsque le SpeedClamp est sous pression Installation dans une conduite d air voir figure 3 1 Connecter le boyau du système aux orifices appropriés en appliquant un enduit à filetage sur l embout mâle Ne pas laisser pénétrer l enduit à l intérieur de l appareil FRL 2 Maintenir le corps de l appareil FRL à l aide d une clé à tube appliq...

Page 4: ...hées Model Modelo Modèle Compact Standard Ref English Español Français Compact Standard No Description Descripción Description Compact Standard Qty 1 SpeedClamp Abrazadera SpeedClamp SpeedClamp 4ZK24 4ZK35 1 2 SpeedClamp wall bracket Abrazadera SpeedClamp SpeedClamp et support mural 4ZK25 4ZK36 1 y apoyo empotrado 3 SpeedClamp wall bracket Apoyo empotrado SpeedClamp Support mural pour SpeedClamp 4...

Reviews: