11
MAINTENANCE
To avoid personal injury, always shut off and unplug the unit and remove all
air pressure from the system before performing any maintenance.
Regular maintenance will ensure trouble-free operation.
DESCRIPTION
TASK
SERVICE
INTERVAL
To prevent corrosion inside the tank, the condensation
must be drained at the end of every workday. Be sure
to wear protective goggles. Relieve the air pressure in
the system and then open the drain valve on the
bottom of the tank.
CLOSE
OPEN
Pull the ring on the safety valve daily to ensure that it is
operating properly and to clear the valve of any
possible obstructions.
Check all connections to insure they are tight. A small
leak of any of part (the tank, hoses, pipe connections
or transfer tubes) will reduce the unit’s performance.
Spray a small amount of soapy water around the area
of the suspected leak with a spray bottle. If bubbles
appear, repair or replace the faulty component. Do not
overtighten any connections.
Before storing the unit for a long period, use an air
blow gun to clean all dust and debris from the
compressor. Disconnect and coil the power cord. Pull
the ring on the safety valve to release all pressure from
the tank. Drain all moisture from the tank. Cover the
entire unit to protect it from moisture and dust.
Drain the tank
Check the
safety valve
Test for
leaks
Storage
Daily
Daily
Monthly
Prior to
storing