General Information
This information is to be used when installing gas
tumblers in countries, and/or on gases, different than
the machine’s factory configuration. Tumblers are
supplied from the factory for operation on Natural Gas
or L.P. Gas in the countries of GB/IE/PT/ES/IT/GR/
LU/CH. To install machines in any other country, or
on any other gas, requires some level of modification.
Models are built in two different configurations:
●
Natural Gas
– regulated/governor
●
Liquefied Petroleum (L.P.) Gas
– not regulated/
no governor
Machines configured for Natural Gas (regulator/
governor) may be converted to L.P. Gas (not regulated/
no governor) with block-open kit, Part No. M400763.
Serial plates are configured for GB/IE/PT/ES/IT/GR/
LU/CH.
Country
Code
Gas Type
Group
Supply
Pressure,
mbar
Burner
Orifice
Pressure,
mbar
Capacity/
Model
Diameter,
mm
Quantity
Burner
Orifice
Part No.
DK/NO/
SE/FI/CZ/
EE/LV/LT/
SI/SK
Natural Gas
H
20
8.9
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
B/P
30
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
DE**
Natural Gas
E
20
8.9
050
075
3.7
3.6
2
3
M401000
M401014
LL
25
12.6
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
B/P
30
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
B/P
50
28.5
050
075
2.1
2.0
2
3
M401003
M400999
NL
Natural Gas
L
25
12.6
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
B/P
30
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
BE/FR*
Natural Gas
E+
20/25
No Governor
050
075
3.0
2.9
2
3
M401017
N/A
L.P. Gas
+
28/37
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
GB/IE/PT/
ES/IT/GR/
LU/CH
Natural Gas
H
20
8.9
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
+
28/37
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
AT**
Natural Gas
H
20
8.9
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
B/P
50
28.5
050
075
2.1
2.0
2
3
M401003
M400999
CY/IS/MT
L.P. Gas
B/P
30
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
Table 1
Summary of Contents for GU050E
Page 2: ......