6.

Connect exhaust system.

•  Dryer must be exhausted to the outdoors

• 

Use 4 in (102 mm) rigid duct

• 

Maximum straight duct length = 65 ft (19.8 m). Each elbow 

deduct 10 ft (3 m)

• 

Sufficient make-up air must be supplied. The free area of any 

opening for outside air must be at least 40 in

2

 (25806 mm

2

)  

per unit

7.

Position and level the unit.

• 

Recommended rear clearance minimum is 2 in (51 mm) for 

utility connections and 6 in (152 mm) when venting through 

rear of unit

• 

Tighten locknut after final adjustment

• 

Place four (4) rubber feet on leveling legs

•  Unit must not rock

Installation (continued)

8.

Wipe out inside of washtub and dryer drum.

9.

Connect washer and dryer to electrical power – on individual 

branch circuit. Refer to serial plate for electrical ratings.

10.

Run washer through one complete cycle to make sure it is  

operating properly and properly leveled.

11.

Check for leaks.

12.

Start dryer and check that dryer is heating.

7.

 

(dryer)

9.

8.

8.

10.
12.

6.

 

(washer)