T
o p l o a d
W
a s h e r
Coin Slide-Op Control Panel
NetMaster
®
Control Panel
Features:
User selectable options
for hot, warm or cold wash
temperatures.
Two speeds
with normal/gentle wash and slow/fast
extract.
Six total cycles
with three “water saver” cycles and three
regular selections with
LEDs
. MEF of 1.26 and Water Factor of 9.5.
Micro-DISPLAY Control Panel (MDC)
Features:
Vacuum Fluorescent Display
for vend price and cycle
time countdown.
Touch Pad Control
with LEDs.
Three Temperature
Selections
for hot, warm or cold water.
Three Fabric Selections
for
Normal, Permanent Press or Delicate. Regular 12 lb extra-large
capacity with 3 lb
small load option. Push-to-Start activation.
MEF of 1.34 and Water Factor of 9.4.
Features:
LED Digital Display
for vend price and cycle time countdown.
Touch Pad Control
with LED.
Four Fabric Cycle Selections
for
Normal/Hot, Normal/Warm, Permanent Press/Warm, Delicate/Cold.
Push-to-Start activation.
MEF of 1.50 and Water Factor of 8.8.
WATER MANAGER ADVANTAGES
NETMASTER CYCLE DEFAULT AND PROGRAMMING
Feature
Default Setting
Options
Wash Time
10 Minutes
0–15 Minutes
Deep Rinse
4 Minutes
0–15 Minutes
Spin
6 Minutes
0–15 Minutes
Vend Price
$1.00
$0.25 - $655
Fabric Selector
Perm Press
Normal or Delicate
Temp Selector
Warm
Hot or Cold
Two-Speed Cycle Operation
Wash/Rinse
Spin/Extract
Cycle
Action
First Rinse
Final Spin
Normal
Normal
High
High
Perm Press**
Normal
Low
High
Delicate
Gentle
Low
High
Two-speed wash and spin cycles. **Standard setting.
NetMaster and MDC models are available with card or coin start operation.
World’s Leading Supplier of Commercial Laundry Equipment
www.speedqueen.com
AM07-500
• High efficiency automatic washers are U.S. DOE
compliant to 2007 commercial washer standards
for energy and water.
• Special multi-housing cycle for superior washability
– Extended wash, rinse and spin times
– Reduced spray rinse to save water
• Low average hot water usage per cycle
– Cold water rinses (factory set)
NetMaster Topload DOE “J1” Testing
Water
Total Water
DOE
Temp
Hot
Cold
Consumption Cycle %
Hot
14.0
15.7
29.7 Gal
14%
Warm
5.4
24.3
29.7 Gal
49%
Cold 0.0
29.7
29.7
Gal
37%
Average Hot Water Per Cycle
4.61 Gal
* Water usages may vary for your particular application.
Coin Slide Topload DOE “J1” Testing
Water
Total Water
DOE
Temp
Hot
Cold
Consumption Cycle %
Hot
15.1
11.0
26.1 Gal
14%
Warm
4.8
21.3
26.1 Gal
49%
Cold 0.0
26.1
26.1
Gal
37%
Average Hot Water Per Cycle
4.48 Gal
* Water usages may vary for your particular application.
MDC Topload DOE “J1” Testing
Water
Total Water
DOE
Temp
Hot
Cold
Consumption Cycle %
Hot
9.1
14.6
23.7 Gal
14%
Warm
3.5
20.2
23.7 Gal
49%
Cold 0.0
23.7
23.7
Gal
37%
Average Hot Water Per Cycle
2.99 Gal
* Water usages may vary for your particular application.
Operational Efficiencies
FEATURES AND OPERATION