background image

T

o p l o a d  

W

a s h e r

Coin Slide-Op Control Panel

NetMaster

®

Control Panel

Features: 

User selectable options

for hot, warm or cold wash 

temperatures. 

Two speeds

with normal/gentle wash and slow/fast 

extract. 

Six total cycles

with three “water saver” cycles and three 

regular selections with 

LEDs

. MEF of 1.26 and Water Factor of 9.5.

Micro-DISPLAY Control Panel (MDC)

Features: 

Vacuum Fluorescent Display

for vend price and cycle 

time countdown. 

Touch Pad Control 

with LEDs. 

Three Temperature

Selections

for hot, warm or cold water.

Three Fabric Selections

for

Normal, Permanent Press or Delicate. Regular 12 lb extra-large 
capacity with 3 lb 

small load option. Push-to-Start activation.

MEF of 1.34 and Water Factor of 9.4.

Features: 

LED Digital Display

for vend price and cycle time countdown.

Touch Pad Control 

with LED. 

Four Fabric Cycle Selections

for 

Normal/Hot, Normal/Warm, Permanent Press/Warm, Delicate/Cold.

Push-to-Start activation. 

MEF of 1.50 and Water Factor of 8.8.

WATER MANAGER ADVANTAGES

NETMASTER CYCLE DEFAULT AND PROGRAMMING

Feature

Default Setting

Options

Wash Time

10 Minutes

0–15 Minutes

Deep Rinse

4 Minutes

0–15 Minutes

Spin

6 Minutes

0–15 Minutes

Vend Price

$1.00

$0.25 - $655

Fabric Selector

Perm Press

Normal or Delicate

Temp Selector

Warm

Hot or Cold

Two-Speed Cycle Operation

Wash/Rinse

Spin/Extract

Cycle

Action

First Rinse

Final Spin

Normal

Normal

High

High

Perm Press**

Normal

Low

High

Delicate

Gentle

Low

High

Two-speed wash and spin cycles. **Standard setting.

NetMaster and MDC models are available with card or coin start operation.

World’s Leading Supplier of Commercial Laundry Equipment

www.speedqueen.com

AM07-500

• High efficiency automatic washers are U.S. DOE 

compliant to 2007 commercial washer standards 
for energy and water.

• Special multi-housing cycle for superior washability

– Extended wash, rinse and spin times
– Reduced spray rinse to save water

• Low average hot water usage per cycle 

– Cold water rinses (factory set)

NetMaster Topload DOE “J1” Testing

Water

Total Water

DOE

Temp

Hot

Cold

Consumption Cycle %

Hot

14.0

15.7

29.7 Gal

14%

Warm

5.4

24.3

29.7 Gal

49%

Cold 0.0

29.7

29.7 

Gal

37%

Average Hot Water Per Cycle

4.61 Gal

* Water usages may vary for your particular application.

Coin Slide Topload DOE “J1” Testing

Water

Total Water

DOE

Temp

Hot

Cold

Consumption Cycle %

Hot

15.1

11.0

26.1 Gal

14%

Warm

4.8

21.3

26.1 Gal

49%

Cold 0.0

26.1

26.1 

Gal

37%

Average Hot Water Per Cycle

4.48 Gal

* Water usages may vary for your particular application.

MDC Topload DOE “J1” Testing

Water

Total Water

DOE

Temp

Hot

Cold

Consumption Cycle %

Hot

9.1

14.6

23.7 Gal

14%

Warm

3.5

20.2

23.7 Gal

49%

Cold 0.0

23.7

23.7 

Gal

37%

Average Hot Water Per Cycle

2.99 Gal

* Water usages may vary for your particular application.

Operational Efficiencies

FEATURES AND OPERATION

Reviews: