-27-
802759
Vacations and Extended
Non-Use
•
To avoid possible property damage due to
flooding, turn off the water supply to the
washer whenever there will be an extended
period of non-use.
Reinstallation of Shipping
Materials
To prevent damage while moving the unit, the
shipping materials MUST be reinstalled.
•
Disconnect washer from electrical supply.
•
While supporting the front access panel,
remove two screws from the bottom edge of
the panel.
•
Gently lower the panel to remove it from the
washer.
•
Place the shock sleeves on all four shock
absorbers. Refer to the illustration below.
•
Insert hooked end of shipping brace into the
open slot of the motor mount.
•
Attach the brace with the five bolts and
washers. Refer to the illustration below.
•
Reinstall front access panel.
Refer to the INSTALLATION INSTRUCTIONS for
proper procedures whenever the washer is moved.
Cleaning Foreign Object Trap
The washer’s pump has a trap that may collect
foreign objects. The trap may need to be cleaned if
water is draining slower than usual. To clean:
•
Disconnect washer from electrical supply.
•
While supporting the front access panel,
remove two screws from the bottom edge of
the panel.
•
Gently lower the panel to remove it from the
washer.
NOTE: The pump may have some water in it. Use
a rag or a container to catch water. If the wash
drum is full of water, use a wet/dry shop vacuum
to catch the water.
•
With rag or vacuum ready, unscrew the cap
on the left side of the pump and remove trap.
•
Clean the debris from the trap.
•
Reinstall the trap and access panel.
•
Reconnect washer to electrical supply.
FLW2182N
FLW21
8
2N
Shock
Sleeves
Bolts and Lockwashers
Motor
Mount
Hooked End of
Shipping Brace