Speed Queen 50 lb Brochure & Specs Download Page 6

Tumbler Specifications

www.speedqueen.com

AO05-203

*All weights are approximatete 

Tumbler models are made to suit a variety of electrical service characteristics. See your Speed Queen distributor for specifications. Features and certifications
may vary by model. For further details on installation refer to Installation, Operation and Maintenance Instructions supplied with the tumbler. Air outlet
diameter – 8” (203 mm). 

Due to continuous product improvements, design and specifications are subject to change without notice. The quality management systems at all Alliance
Laundry Systems manufacturing facilities are registered as ISO9001:2000 compliant.

©Copyright 2005 Alliance Laundry Systems LLC

®

50 lb

75 lb

Cylinder Size

- in (mm)

37” x 30” (939 x 762)

37” x 36” (939 x 914)

(diameter x depth)

Dry Weight Capacity 

-

50 (23)

75 (34)

lb (kg)

Dimensions 

- in (mm)

Gas and Electric Models:

Gas and Electric Models: 

(height x width x depth)

76 5/8" x 38 5/8" x 47” 

76 5/8" x 38 5/8" x 53”

(1946 x 981 x 1194)

(1946 x 981 x 1346) 

Steam Models:

Steam Models:

80" x 38 5/8" x 47”

80" x 38 5/8" x 53” 

(2032 x 981 x 1194)

(2032 x 981 x 1346)

Motor HP

Non- Reversing 1/2 HP Reversing 1/3-1/3 HP

Non- Reversing 3/4 HP Reversing 1/3-1/3 HP

Energy Data 

Gas Models:

Gas Models:

120,000 Btu/hour (30,240 kcal/hr)

165,000 Btu/hour (41,580 kcal/hr)

Steam Models:

Steam Models:

At 100 psig (6.9 bar): 5.1 BHP,

At 100 psig (6.9 bar): 6.1 BHP,

177,500 Btu/hr (52 kW)

210,346 Btu/hr (61.6 kW)

At 15 psig (1.0 bar): 3.4 BHP,

At 15 psig (1.0 bar): 4.1 BHP,

118,800 Btu/hr (34.8 kW)

140,810 Btu/hr (41.2 kW)

Electrical Specifications

Gas and Steam Models:

Gas and Steam Models:

and Circuit Requirements

Amps

Amps

Non-Rev

Rev

Non-Rev

Rev

120/60/1

9.3

N/A

120/60/1

13.8

N/A

200–208/240/60/1    

5.1/5.1

N/A

200–208/240/60/1 

7.6/7.6

N/A

200–208/240/60/3 2.8/2.8

4  200–208/240/60/3

3.8/3.8

4.3

200/50/3

3.3

4.2

200/50/3

3.5

4.5

440/60/3 (Steam)

1.4

1.9

440/60/3 (Steam)

1.9

2.1

460-480/60/3

1.4

1.9

460-480/60/3

1.9

2.1

230-240/50/1

6.3

6.9 230-240/50/1

6.7

7.0

230-240/50/3

3.1

4.3

380/400-415/50/3

3.5

4.9

380/400-415/50/3

1.6

2.0 380/400–415/50/3

1.8

2.1

Electric Models – 30 kW

Electric Models – 30 kW

Non-Rev

Rev

Non-Rev

Rev

200-208/60/3

89

88

200-208/60/3

89

88

240/60/3

79

78

240/60/3

79

77

200/50/3

84

85

200/50/3

84

85

230/50/3

73

75

230/50/3

73

75

440/60/3

41

41

440/60/3

41

41

480/60/3

38

38

480/60/3

38

38

240/50/3

79

78

240/50/3

79

78

380/50/3

47

48

380/50/3

47

48

400-415/50/3

43

44

415/50/3

45

45

Electric Models – 21 kW

Non-Rev

Rev

240/50/1

93

95

0/60/3  

4 amp  

4 amp

208–240/60/3   4 amp           6 amp

Airflow, CFM 

-

750 (354)

60 Hz Gas and Steam Models:

cfm (liters/sec)

750 cfm (354 liters/sec.)

920 (434)

All Electric and 50 Hz Gas and Steam Models:

750 (354)

Water Inlet Size

(1) 3/4" Hose Connection

(1) 3/4" Hose Connection

(C.A.R.E. System)

Net Weight 

- lb (kg)

545 (247)

615 (279)

Shipping Weight* 

Standard:

Slat Crate:

Standard:

Slat Crate:

lb (kg)

602 (273)   

669 (303)

677 (307)

742 (337)

Agency Approvals

Gas Models:

Gas Models:

CSA Star, CSAus, CE

CSA Star, CSAus, CE

Electric and Steam Models:

Electric and Steam Models:

CSAus, CE

CSAus, CE

Reviews: