![Spectrum WatchDog 3665R Product Manual Download Page 3](http://html.mh-extra.com/html/spectrum/watchdog-3665r/watchdog-3665r_product-manual_1344394003.webp)
3
WatchDog Data
Logger inside
radiation shield
Locate the rain collector
in an open area which
is within reach of the
external WatchDog
data port (Channel A).
One rain collector per
weather station.
For greatest accuracy, you should thoroughly clean the rain
collector at least once or twice a year. Disconnect the logger
from the rain collector to avoid any inadvertent counts on the
logger when cleaning. Your gauge should be cleaned using a
mild detergent.
Inspect the sensors frequently to make certain the sensors are
still level and clear of obstructions.
Rain collector adjustor
If rain collector is not reading correctly (or at all)
1. 1. Launch the logger or weather station so you can see the rain
measurements on the LCD (this step is not necessary if the rain col-
lector is attached to a WatchDog 2000 Series Mini or Weather Sta-
tion).
2. Check the inside of the rain bucket for debris such as leaves that
may be blocking the grid at the bottom of the bucket. Remove the rain
bucket from the base and check for any obstacles (spider webs, de-
bris, etc.) that may be preventing the tipping spoon from moving freely.
If the hole beneath the grid gets clogged with dirt, the cotter key can
be removed to allow it to be cleared.
3.
Manually move the tipping spoon back and forth several times.
Check the LCD after it has updated to see if these tips have been re-
corded. Do this several times.