Spectrum BB24V1U User Manual Download Page 4

3

Battery Replacement (Technician Reference Only)

As long as utility power is on, you can leave BB24V1U and other connected equipment powered on while replacing a battery. 

Button-Alarm Silence

When BB24V1U is operating under battery mode, or its battery power is low, the audible alarm is turned on.

Press and hold the button for 5 seconds. BB24V1U will beep once to confirm that audible alarms have been disabled permanently.

2

  To restore the audible alarm, press and hold the button for 5 seconds. BB24V1U will beep twice to confirm that    

 

 

audible alarms have been turned on.

Button-Cold Start

Cold start uses battery power when BB24V1U is powered off, and no utility power is available.
Before using the cold start feature, make sure the battery is properly charged and installed.
To turn on the cold start feature, press and hold the button until 3 LED indicators are on.

LED Indicator

STEP 1:

A

 Loosen the screw  

  from the enclosure.

STEP 2:

A

 Slide off the  

  battery cover on  
  the back of the  
 BB24V1U.

STEP 3:

A

 Remove the battery  

  from the enclosure.

B

  Disconnect both  

  battery cable       
 connectors.

STEP 4:

A

 Install a new battery  

  by connecting the  
  red wire to positive  
  terminal and the  
  black wire to the  
  negative terminal.

Insert the battery into  

 BB24V1U.

STEP 5:

A

 Replace the battery    

  cover to resume normal
 operation.

B

 Tighten the screw into   

  the enclosure.

Fail

Mute

BLUE/RED

RED

BLUE

Battery replacement required. Alarm beeps once every 15 minutes. The LED also illuminates 
when the battery is absent or when battery is in protection state then turn off the output power.

Press and hold the “Mute” button for 5 seconds to silence the audible alarm.  
The LED will be on.

USC cable loss: The Status LED is easing between BLUE and RED for 120 seconds.

Note: After 120 seconds, the Status LED returns to its normal operational state (Battery 
charging/Battery mode).

Battery charging mode: The Status LED is easing BLUE. The battery level is between 1%~99%.
Battery mode: Indicates the battery capacity.

  Battery capacity > 20%: BLUE LED is on.

2

   Battery capacity between 10% and 20%: RED LED is on, and alarm beeps 4 times  

 

per minute.

3

   Battery capacity 

 10%: RED LED blinks, and alarm beeps 4 times per minute.

Indicator

Color 

Condition

Status

Summary of Contents for BB24V1U

Page 1: ...BB24V1U Battery User Manual ...

Page 2: ...on There are no user serviceable parts inside the unit including the battery Please contact us or our dealer for service When replacing batteries the replacement should have the same rating Listed Certified Valve Regulated Lead Acid Battery 12V max 10Ah Before replacing batteries remove conductive jewelry such as chains watches and rings and use tools with insulated handles High energy passed thro...

Page 3: ...d DC power cable DC jack Wall Mount 1 LED indicator 2 Button 3 AC power cable connector 4 DC power cable connector 5 UART serial communications USC connector 6 Battery cover Number Description Mounting Surface Max 5 16 1 1 5 1 8 Max 3 16 STEP 1 Connect the AC cable to an electrical outlet STEP 3 Use the wall mount template and a screwdriver to position screws on a wall Hang BB24V1U on the screws S...

Page 4: ...B24V1U STEP 3 A Remove the battery from the enclosure B Disconnect both battery cable connectors STEP 4 A Install a new battery by connecting the red wire to positive terminal and the black wire to the negative terminal B Insert the battery into BB24V1U STEP 5 A Replace the battery cover to resume normal operation B Tighten the screw into the enclosure Fail Mute BLUE RED RED BLUE Batteryreplacemen...

Page 5: ...al Message Voltage Range 100Vac 240Vac Frequency Range 50 60Hz Output On Battery Output Voltage 12Vdc Continuous Power Capability 36W Efficiency Max Load 80 Battery Battery Type Numbers of Battery 12Vdc 10Ah x 1 Typical Recharge Time 24 Hours Replaceable Surge Protection and Filtering Lightning Surge Protection Management Battery Auto Charge Yes Physical Dimensions LxWxD 18 5cm x 8 5cm x 18 7cm We...

Page 6: ...of the PRODUCT could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities Charter expressly disclaims any express or implied warranty of fitness for High Risk Activities Charter does not authorize use of any PRODUCT in any High Risk activities ANY SUCH USE IS IMP...

Reviews: