background image

Installation 

The Pressure Transducer includes a 6 foot cable  that 

is plugged into an available external port on an original 

WatchDog  data  logger,  WatchDog  micro

-

station, 

WatchDog mini

-

station,  or WatchDog full weather sta-

tion.  To install the transducer: 

   

 

1)  Remove vacuum gauge from Irrometer 

Tensiometer with a 

9/16” 

wrench.

 

2)  Apply thread sealant and screw the transducerinto 

the Irrometer Tensiometer. Tighten with a wrench.

 

3)  Use a thread sealant on fittings. Screw the vacuum 

gauge into the transducer. The gauge should be facing 

up.

 

4)  Prepare the Tensiometer for field installation as per 

IRROMETER

S instructions.

 

Screw this end 

into Tensiometer

 

Screw Vacuum 

gauge into these 

threads

 

Cable to 

 

WatchDog

 

Specifications 

Accuracy

 

± 2%

 

Resolution

 

1000 Series

 

2000 Series

 

 

0.097 kPa

 

0.025 kPa

 

Note: 

The thread 

size for the trans-

ducer is not com-

patible with the 

mini tensiometers

 

Reviews: