26
Light quantity is measured in a daily light integral (DLI)
which refers to the total amount of light a plant receives in
one day. A plant requires a minimum DLI just like it re-
quires a certain amount of rainfall. The following values
were obtained from a set of experiments performed at
Clemson University.
SPRING EXPERIMENT
The spring experiment measured plant development at 0%
shade (18 mol/day), 25% shade (12 mol/day), 50% shade
(6 mol/day), and 75% shade (3 mol/day).
Plant
Commercially
Acceptable Quality
Highest Quality
Begonia
6 mol/day
12 to 18 mol/day
Pansy
N/A
18 mol/day
Marigold
6 mol/day
N/A
Angelonia
12 mol/day
18 mol/day
Petunia
N/A
N/A
Impatiens
3 mol/day
6 to 12 mol/day
Plant-Specific