2
Thank you for purchasing an AutoDialer. This manual will
familiarize you with the features and operation of your new
AutoDialer. Please read this manual thoroughly before using
your instrument.
Item #3419 AutoDialer is compatible with #3672 Alarm Out-
put Module or any other continuous, momentary, normally
closed (NC) or normally open (NO) dry contact voltage sen-
sor. The AutoDialer will dial up to four numbers with a re-
corded message up to 16 seconds when the sensor or output
module opens or closes the circuit.
The following instructions will simplify installation of an
AutoDialer with your WatchDog Weather Station.
Normally Open Activation Hookup
With WatchDog and #3672 Alarm Output Module
Using Your AutoDialer
1. Program the AutoDialer message and number(s) per the
instructions included with the unit.
2. Program the AutoDialer to normally open (NO) and
momentary activation, no exit or entry delay per the in-
structions on pg. 11 of your AutoDialer manual.
3. Trim or cut off the U-shaped terminals on the 4 wire
leads on the AutoDialer power/alarm cable so they will
fit into the terminal connectors on the Alarm Output
Module. Splice wire extension if needed.
4. Connect the RED and YELLOW leads from the Auto-
Dialer power/alarm cable to the COM terminal on the
Alarm Output Module.
5. Connect the WHITE and BLACK leads from the Auto-
Dialer power/alarm cable to the N.O. terminal on the
Alarm Output Module.
6. Set the Alarm Output in the SpecWare™ launch options
screen to the desired parameters and launch the station.