15
Measurement
Units
Percent volumetric water content
Resolution
0.1%
Accuracy
±3.0% volumetric water content
with electrical conductivity < 2 dS m
–1
Range
0% to saturation (Saturation is typical-
ly around 50% volumetric water.)
Power
4 AAA alkaline batteries
Approximately 12 month life
Display
16 character, 2 line LCD
Weight
1.5 lbs. (0.68 kg)
Probe Head
Dimensions
3.1” x 3” x 1”
(7.8cm x 7.5cm x 2.5cm)
Rod Dimensions Length : 1.5” (3.8cm), 3” (7.6cm),
4.7” (12cm) or 7.9” (20cm)
Diameter: 0.2” (0.5cm)
Spacing: 1.3” (3.3cm)
Specifications
The meter’s LCD screen will display the data in one of
three modes (see Meter Operation p. 4):
1. Volumetric water content - in Standard or High Clay
mode (see p. 8).
2.
Relative water content - up to 2 RWC modes can be
established (see p. 10).
3.
Measurement period - in microseconds