![Spectronik PRREG User Manual Download Page 7](http://html.mh-extra.com/html/spectronik/prreg/prreg_user-manual_1344203007.webp)
1. Remove the blocker at (6) that was in place during gas filling process.
2. Connect the gas outlet at (6) to your desired application, e.g. to the inlet of the supply valve of a fuel cell
system.
3. Open the manual valve (2) by turning it anti-clockwise slowly until the end. Gas from inside the carbon fiber
cylinder will now flow out through (6).
4. To turn off the gas at the end of usage, shut off the manual valve (2) by turning it clockwise.
•
Wear safety goggles and gloves at all times.
•
Ensure connections are firm and secure, but do not use excessive force to over-tighten.
•
Never operate PRREG at inlet pressure beyond 350bar.
•
Carbon fiber cylinder will become warm when filled with Hydrogen gas. Never fill a carbon fiber cylinder too
quickly. If you are using a booster pump, it is advisable to pause the filling process every 30-50bar to prevent
over temperature.
When not in use, keep PRREG in its original box and store it in a cool, dry place.
Using the filled Carbon Fiber Cylinder
Reminder
Storage
CHAPTER 3 | OPERATING PROCEDURES