Page 1: ...ame Simulator Model FS 1400 User Manual Document ref TM380302 Rev 6 April 2017 8200 Market Blvd Chanhassen MN 55317 USA Phone 1 973 239 8398 Fax 1 973 239 7614 Website www spectrex net Email spectrex spectrex net ...

Page 2: ......

Page 3: ...o have or will have responsibility for using maintaining or servicing the product The Simulator is not field repairable due to the meticulous alignment and calibration of the sensors and the respective circuits Do not attempt to modify or repair the internal circuits or change their settings as this will impair the system s performance and void the SPECTREX product warranty Warranty SPECTREX agree...

Page 4: ...irst Release Ian Buchanan Eric Zinn 1 May 2016 Second Release Ian Buchanan Eric Zinn 2 July 2016 Third Release Ian Buchanan Eric Zinn 3 January 2017 Fourth Release Jay Cooley Ian Buchanan 4 February 2017 Fifth Release Jay Cooley Ian Buchanan 5 February 2017 Sixth Release Jay Cooley Ian Buchanan 6 April 2017 Seventh Release Jay Cooley Shaul Serero ...

Page 5: ...14 1 7 1 General Instructions 14 1 7 2 Special Conditions for Safe Use 15 2 Operation Instructions 17 2 1 Ordering Information 17 2 2 Unpacking 17 2 3 Operating Instructions 18 2 4 Detection Ranges 19 2 5 Charging the Battery 20 2 6 Maintenance 21 2 7 Troubleshooting 22 2 8 Technical Specifications 22 2 8 1 General Specifications 22 2 8 2 Electrical Specifications 22 2 8 3 Physical Specifications ...

Page 6: ...res Figure 1 Flame Simulator Side View 12 Figure 2 Flame Simulator Rear View 13 Figure 3 Flame Simulator Front View 13 Figure 4 Flame Simulator Battery Replacement 21 List of Tables Table 1 Flame Simulator Compatability 18 Table 2 Detection Ranges per Detector Flame Simulator 19 ...

Page 7: ...s on how to operate and maintain the simulator This guide includes the following chapters Chapter 1 Introduction provides a general overview of the product principles of operation and performance considerations Chapter 2 Operation Instructions describes how to operate the simulator including instructions regarding replacement and charging of the battery ...

Page 8: ......

Page 9: ...an open flame SPECTREX flame simulators are ATEX certified EExd for use in hazardous zones 1 2 21 and 22 and are powered by rechargeable lithium ion batteries When fully charged the flame simulator operates for at least 1 000 tests without recharging Starting fires in hazardous locations is not permitted and can be dangerous in non hazardous locations Using an external portable SPECTREX flame simu...

Page 10: ...r from a distance of up to 12m Rechargeable battery included Operates at least 1 000 tests before battery recharge is necessary 1 3 Principles of Operation The FS 1400 emits IR energy which is filtered to emit electromagnetic radiation in a unique sequential pattern corresponding to and recognizable as a fire by the SharpEye IR3 Flame Detector The simulator includes a reflector that accumulates th...

Page 11: ...en activations Fault Status Low Battery The laser flashes 3 times in 3 consecutive cycles IR radiation will be activated IR Fault The laser flashes 3 times in 5 consecutive cycles IR radiation will not be activated Total Failure The laser does not turn on IR radiation will not be activated 1 5 Product Certification The Flame Simulator Model FS 1400 is certified to ATEX and IECEx Ex II 2 G D Ex db ...

Page 12: ...hamber includes a PC Board with an IR source or halogen lamp The source or lamp is assembled on the PC Board and emits light through the sapphire window The battery chamber includes a battery pack containing 4 lithium ion batteries measuring a total of 14 8VDC and 2 2Ah The battery pack can be replaced easily by opening the back cover This procedure must be executed in a safe area using only a SPE...

Page 13: ...TM380302 Rev 6 April 2017 Simulator Structure 13 Figure 2 Flame Simulator Rear View Figure 3 Flame Simulator Front View ...

Page 14: ... C Inspection and maintenance of this equipment should be performed by suitable trained personnel in accordance with the applicable code of practice e g EN 60079 17 Repair of this equipment should be performed by suitable trained personnel in accordance with the applicable code of practice e g EN 60079 19 Certification of this equipment relies upon use of the following materials in its constructio...

Page 15: ...IEC EN 60079 1 2007 for IIB H2 as detailed below Flamepath Description Type of Joint Minimum Width L mm Maximum Gap ic mm Joint formed by window against the enclosure Flanged 10 75 0 02 Enclosure end cap spigot Cylindrical 15 0 08 Gaps should not be machined to be any larger than the values of ic and width should not be modified to be any smaller than the values of L as shown in the table above Th...

Page 16: ......

Page 17: ...he kit is supplied in a carry case that includes Flame Simulator FS 1400 Charger Tool Kit Technical Manual TM380302 2 2 Unpacking Verify that you have received the following components Delivery form Flame simulator with integral battery Battery charger Tool keys User manual FAT forms EC declaration Storage case ...

Page 18: ... using the correct simulator that fits the tested detector per the following table Simulator Compatible with FS 1400 40 40M Table 1 Flame Simulator Compatability 2 Verify you are at the correct distance from the detector according to the type of detector and the detector sensitivity see Section 2 4 3 For FS 1400 Using the mechanical sight aim the flame simulator toward the center of the detector P...

Page 19: ... Distance ft m FS 1400 40 40M 50 15 6 6 2 100 30 19 6 6 150 45 29 5 9 215 65 39 3 12 Table 2 Detection Ranges per Detector Flame Simulator Notes The minimum distance from the detector is 30 75cm At extreme temperatures there is a 15 reduction in the testing range Important Keep the flame simulator in a safe place when not in use ...

Page 20: ...simulator model FRIWO MPP15 with maximum charging voltage of 16 8V 4 2V x 4 and maximum current of 700mA 7 Charge for a maximum of 2 3 hours until the green LED on the charger lights 8 Disconnect the charger 9 Insert the battery into the flame simulator 10 Screw on the locking disc Figure 4 Item 4 11 Screw on the back cover Figure 1 and Figure 4 Item 3 12 Lock the back cover with the locking screw...

Page 21: ...acement 2 6 Maintenance Ensure the flame simulator is charged before operation Ensure the reflector and window are clean Before replacing the battery check that you have a SPECTREX Battery Pack P N 380004 When the simulator is not in use recharge at least every 6 months Warning Use only a SPECTREX Replacement Battery Pack P N 380004 ...

Page 22: ...for repair Flame simulator seems to work properly but does not activate the detector 1 Verify that you are at the correct distance 2 Verify that the flame detector is at the correct sensitivity 3 Verify that the flame detector is operating 4 Verify that the flame detector is clean 2 8 Technical Specifications 2 8 1 General Specifications Temperature Range 4 F to 122 F 20 C to 50 C Vibration Protec...

Page 23: ... Gb X Ex ib op is tb IIIC T135 C Db X 20 C Ta 50 C Water and Dust Tight IP65 2 8 4 EMI Compatibility Immunity Tests Title Basic Standard Level to be tested Electrostatic Discharge ESD IEC 61000 4 2 6kV 8kV contact air Radiated Electromagnetic Field IEC 61000 4 3 20V m 80MHz 1GHz 10V m 1 4 2GHz 3V m 2 0 2 7GHz Conducted Disturbances IEC 61000 4 6 10 Vrms 150kHz 80MHz Immunity to Main Supply Voltage...

Page 24: ......

Page 25: ......

Page 26: ...Website www spectrex net Your Local SPECTREX Office Texas USA Mr Jay Cooley Regional Sales Manager 16203 Park Row Suite 150 Houston Texas 77084 USA Phone 1 832 321 5229 Email jay cooley emerson com Far East Mr Deryk Walker Regional Sales Manager 59 Fen Ji Hu Danshui Taipei County 25163 Taiwan ROC Phone 886 2 8626 2893 Mobile 886 926 664 232 Email deryk walker emerson com ...