All lamps are connected to the transformer via 1 cable
12VAC
230VAC
Max cable length
JUNCTION
BOX
JUNCTION
BOX
4m cable attached to lamp
Separate cable (not included)
Toroïdal transformer is preferred because of better efficiency
LAMP TYPE
MAX CABLE LENGTH BY CABLE SECTION
QTY
LAMPS
2,5 mm
2
4,0 mm
2
6,0 mm
2
10,0 mm
2
VA
TRANSFORMER
(12VAC) *
* The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps.
These cable lenghts are calculated with worst case voltage drops in the electrical wiring.
PLS300(B)
PLS400(B)
PLS700(B)
PLW400(B)
PLW300(B)
PLW700(B)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
120m
60m
35m
25m
100m
50m
30m
25m
150m
75m
50m
35m
85m
40m
25m
20m
180m
90m
60m
40m
160m
80m
50m
40m
200m
120m
80m
60m
140m
70m
45m
35m
200m
200m
150m
110m
200m
200m
130m
100m
200m
200m
200m
150m
200m
170m
110m
85m
200m
140m
90m
65m
200m
120m
80m
60m
200m
180m
120m
90m
200m
100m
70m
50m