SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
4
SYSTEM SPECIFICATIONS:
Sediment Prefilter
0.5 micron MicroTec™ sediment prefilter (SF-MT-0.5-10)
Carbon Filter
RO Membrane Type
0.5 micron carbon block prefilter (CF-0.5-10)
Thin-Film Composite (TFC)
Rejection Rate
Greater than 96% average
Input Water Pressure
60 psi (4.15 bar) line pressure*
Input Water Temp
77°F (25°C)
Recovery Rate
25% (i.e. 25% of the water will be collected as pure water)
Nominal Membrane Flow Rates @ 60 psi & 77° F:
GPD (lpd)
Product Water Flow Rate
Concentrate Flow Rate
90 (340)
236 ml/min
708 ml/min
180 (680)
473 ml/min
1419 ml/min
Reverse Osmosis Feed Water Requirements:
For the 1 year TFC membrane prorated warranty to be honored, the following conditions
must be met:
Operating Pressure*
40 – 80 psi (2.75 – 5.5 bar)
pH Range
3 – 11
Maximum Temperature
113° F (45° C)
Maximum Turbidity
1.0 NTU
Maximum Silt Density Index
5.0 (based on 15 min. test time)
Maximum Chlorine
less than 0.1 ppm
Maximum TDS
2000 ppm
Maximum Hardness
10 grains (170 ppm as CaCO3)
Maximum Iron
less than 0.1 ppm
Maximum Manganese
less than 0.1 ppm
Maximum Hydrogen Sulfide
0 ppm
Langelier Saturation Index
LSI must be negative
*Operating pressure less than 40 psi may require a booster pump:
less than 49 GPD use BPLF-MO-115(-230),
more than 49 GPD use BPHF-MO-115(-230)