4. Site
Preparation
As shown in the system diagram in the previous section, the NetLink Telephony Gateway
is connected to both the Ethernet switch and the wired telephone system, the NetLink
SVP Server is connected to the Ethernet switch only. The specifications covered here
allow for great flexibility in physical placement of the components within stated
guidelines.
4.1 Required
Materials
The following equipment must be provided by the customer.
•
Power Outlet(s)
– must accept SpectraLink provided AC adapter, one for each
NetLink Telephony Gateway and one for the NetLink SVP Server (if required).
•
Cross-Connect Block
–
required to connect the PBX ports to the NetLink
Telephony Gateway(s).
•
25 Pair Cables
–
RJ-21 male at NetLink Telephony Gateway end, required to
connect each NetLink Telephony Gateway to the cross-connect blocks.
•
Backboard space
–
the NetLink Telephony Gateway and the NetLink SVP
Server are designed to be wall mounted to ¾” plywood securely screwed to the
wall.
•
Screws
–
required to mount the NetLink Telephony Gateway and the NetLink
SVP Server (if required) to the wall. Four #8 - ¾” panhead wood screws (or
similar device) are required for each component.
•
10BaseT Cables
–
RJ-45 connector at each NetLink Telephony Gateway.
Connection to Ethernet switch.
•
CAT 5 Cable
–
RJ-45 connector at the NetLink SVP Server. Connection to
Ethernet switch.
•
Modem Cable
–
DB-9 female, null-modem cable. Required for initial setup of the
NetLink Telephony Gateway and SVP Server.
4.2 LAN
Requirements
Network Infrastructure
The NetLink Telephony Gateway connects to your local area network (LAN). To
provide adequate bandwidth and limit collisions, an Ethernet switch is required. The
traffic between the NetLink Telephony Gateway and wireless LAN APs should be
isolated as much as possible to avoid additional latency. The NetLink Telephony
Gateway and APs must be on the same logical IP subnet. Inter-subnet roaming is not
permitted for wireless devices.
Each NetLink Telephony Gateway to be installed requires a 10 Mb/s switched Ethernet
connection.